No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00810007630762 ZB-K030 ZB-K030 MANDIBLE RECONSTRUCTION, SURGICAL PLANNING KIT W/ PLATE DESIGN DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuPlan® System
2 00810007630755 ZB-K021 ZB-K021 MIDFACE RECONSTRUCTION, SURGICAL GUIDE DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuPlan® System
3 00810007630748 ZB-K020-R ZB-K020-R MIDFACE RECONSTRUCTION, SURGICAL PLANNING KIT - REPORT DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuPlan® System
4 00810007630731 ZB-K020 ZB-K020 MIDFACE RECONSTRUCTION, SURGICAL PLANNING KIT DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuPlan® System
5 00810007630724 ZB-K011 ZB-K011 MANDIBLE RECONSTRUCTION, SURGICAL GUIDE DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuPlan® System
6 00810007630700 ZB-K010 ZB-K010 MANDIBLE RECONSTRUCTION, SURGICAL PLANNING KIT DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuPlan® System
7 00810007630694 ZB-K004 ZB-K004 ORTHOGNATHIC, SURGICAL GUIDE DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuPlan® System
8 00810007630687 ZB-K003 ZB-K003 ORTHOGNATHIC, 3D PRINTED DENTAL MODELS DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuPlan® System
9 00810007630670 ZB-K002 ZB-K002 ORTHOGNATHIC, FINAL SPLINT DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuPlan® System
10 00810007630663 ZB-K001 ZB-K001 ORTHOGNATHIC, INTERMEDIATE SPLINT DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuPlan® System
11 00810007630656 ZB-K000-R ZB-K000-R ORTHOGNATHIC, SURGICAL PLANNING KIT - REPORT DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuPlan® System
12 00810007630649 ZB-K000 ZB-K000 ORTHOGNATHIC, SURGICAL PLANNING KIT DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuPlan® System
13 00810007631103 ZB-3D208 ZB-3D208 ANATOMICAL MODEL, RIB, SINGLE DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuModel®
14 00810007631097 ZB-K036 ZB-K036 MANDIBLE RECONSTRUCTION, SURGICAL PLANNING KIT BUNDLED W/ ACCUPLATE, NO GUIDES JEY Plate, Bone 2 AccuPlate
15 00810007631080 ZB-K035 ZB-K035 MANDIBLE RECONSTRUCTION, SURGICAL PLANNING KIT BUNDLED W/ ACCUPLATE JEY Plate, Bone 2 AccuPlate
16 00810007630793 ZB-3D101 ZB-3D101 ANATOMICAL MODEL, IMPLANT MODEL DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuModel®
17 00810007630861 ZB-3D108 ZB-3D108 ANATOMICAL MODEL, FIBULA DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuModel®
18 00810007630854 ZB-3D207 ZB-3D207 ANATOMICAL MODEL, SKULL AND MANDIBLE (FUSED) DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuModel®
19 00810007630847 ZB-3D206 ZB-3D206 ANATOMICAL MODEL, SKULL DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuModel®
20 00810007630830 ZB-3D204 ZB-3D204 ANATOMICAL MODEL, MANDIBLE AND MAXILLA DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuModel®
21 00810007630823 ZB-3D203 ZB-3D203 ANATOMICAL MODEL, MAXILLA DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuModel®
22 00810007630816 ZB-3D202 ZB-3D202 ANATOMICAL MODEL, MANDIBLE DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuModel®
23 00810007630809 ZB-3D102 ZB-3D102 ANATOMICAL MODEL, GRAFT DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuModel®
24 00810007630786 ZB-3D100 ZB-3D100 ANATOMICAL MODEL, HOST BONE PERI-DEFECT DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuModel®
25 00810007630779 ZB-3D-M ZB-3D-M ANATOMICAL MODEL, MISCELLANEOUS DZJ,LLZ Driver, Wire, And Bone Drill, Manual,System, Image Processing, Radiological 2 AccuModel®
26 00810007630588 MC-K036 MC-K036 MANDIBLE RECONSTRUCTION, SURGICAL PLANNING KIT BUNDLED WITH ACCUPLATE, NO GUIDES JEY Plate, Bone 2 AccuPlate
27 00810007630571 MC-PLT012 MC-PLT012 MANDIBLE, 2.6 FULL JEY Plate, Bone 2 AccuPlate
28 00810007630564 MC-PLT011 MC-PLT011 MANDIBLE, 2.6 DOUBLE ANGLE JEY Plate, Bone 2 AccuPlate
29 00810007630557 MC-PLT010 MC-PLT010 MANDIBLE, 2.6 HEMI JEY Plate, Bone 2 AccuPlate
30 00810007630540 MC-PLT009 MC-PLT009 MANDIBLE, 2.6 STRAIGHT JEY Plate, Bone 2 AccuPlate
31 00810007630526 MC-PLT008 MC-PLT008 MANDIBLE, 2.8 FULL JEY Plate, Bone 2 AccuPlate
32 00810007630519 MC-PLT007 MC-PLT007 MANDIBLE, 2.8 DOUBLE ANGLE JEY Plate, Bone 2 AccuPlate
33 00810007630502 MC-PLT006 MC-PLT006 MANDIBLE, 2.8 HEMI JEY Plate, Bone 2 AccuPlate
34 00810007630496 MC-PLT005 MC-PLT005 MANDIBLE, 2.8 STRAIGHT JEY Plate, Bone 2 AccuPlate
35 00810007630489 MC-PLT004 MC-PLT004 MANDIBLE, 2.0 FULL JEY Plate, Bone 2 AccuPlate
36 00810007630472 MC-PLT003 MC-PLT003 MANDIBLE, 2.0 DOUBLE ANGLE JEY Plate, Bone 2 AccuPlate
37 00810007630465 MC-PLT002 MC-PLT002 MANDIBLE, 2.0 HEMI JEY Plate, Bone 2 AccuPlate
38 00810007630458 MC-PLT001 MC-PLT001 MANDIBLE, 2.0 STRAIGHT JEY Plate, Bone 2 AccuPlate
39 00810007630410 MC-K035 MC-K035 MANDIBLE RECONSTRUCTION, SURGICAL PLANNING KIT WITH ACCUPLATE BUNDLE JEY Plate, Bone 2 AccuPlate
40 00810007631042 MC-AST20 MC-AST20 Titanium Cranial Implant, Medium GXN Plate, Cranioplasty, Preformed, Non-Alterable 2 AccuShape® Titanium Patient-Specific Cranial Implant
41 00810007631035 MC-AST10 MC-AST10 Titanium Cranial Implant, Small GXN Plate, Cranioplasty, Preformed, Non-Alterable 2 AccuShape® Titanium Patient-Specific Cranial Implant
42 00810007631028 ZB-AST40 ZB-AST40 Titanium Cranial Implant, Extra Large GXN Plate, Cranioplasty, Preformed, Non-Alterable 2 AccuShape® Titanium Patient-Specific Cranial Implant
43 00810007631011 ZB-AST30 ZB-AST30 Titanium Cranial Implant, Large GXN Plate, Cranioplasty, Preformed, Non-Alterable 2 AccuShape® Titanium Patient-Specific Cranial Implant
44 00810007631004 ZB-AST20 ZB-AST20 Titanium Cranial Implant, Medium GXN Plate, Cranioplasty, Preformed, Non-Alterable 2 AccuShape® Titanium Patient-Specific Cranial Implant
45 00810007630984 ZB-PLT012 ZB-PLT012 MANDIBLE, 2.6 FULL JEY Plate, Bone 2 AccuPlate® Patient-Specific Plate
46 00810007630977 ZB-PLT011 ZB-PLT011 MANDIBLE, 2.6 DOUBLE ANGLE JEY Plate, Bone 2 AccuPlate® Patient-Specific Plate
47 00810007630960 ZB-PLT010 ZB-PLT010 MANDIBLE, 2.6 HEMI JEY Plate, Bone 2 AccuPlate® Patient-Specific Plate
48 00810007630953 ZB-PLT009 ZB-PLT009 MANDIBLE, 2.6 STRAIGHT JEY Plate, Bone 2 AccuPlate® Patient-Specific Plate
49 00810007630946 ZB-PLT008 ZB-PLT008 MANDIBLE, 2.8 FULL JEY Plate, Bone 2 AccuPlate® Patient-Specific Plate
50 00810007630939 ZB-PLT007 ZB-PLT007 MANDIBLE, 2.8 DOUBLE ANGLE JEY Plate, Bone 2 AccuPlate® Patient-Specific Plate
Other products with the same Product Codes "DZJ, LLZ"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 D875403051 1 A cloud-based, PACS-server software application that gives dental organizations A cloud-based, PACS-server software application that gives dental organizations web access to patient images that have been captured from any DICOM-enabled device. Apex Cloud Software MASTERLINK LLC
2 D875400101 1 Dental imaging capture, enhance and display software. Apex Capture Software MASTERLINK LLC
3 D848CURVEIMAGE0 CURVE-IMAGE-I Curve Image™ is a cloud-based dental image acquisition and management system tha Curve Image™ is a cloud-based dental image acquisition and management system that provides Internet access to an image library for each patient in a practice. It also provides tools for dental practices to manipulate patient images and both acquire and upload new images in industry standard formats. Images can be annotated and tagged, and are available for both diagnostic and non-diagnostic use. All of these actions are performed from a secure website, after entering user credentials, similar to other commonly used online applications. The system can be accessed by the user via an internet connection and does not require any software installation on the user's computer. Curve Image™ CURVE DENTAL LTD
4 D848CURVEHERO0 CURVE-HERO-I Curve Dental® develops and markets a cloud-based dental practice management syst Curve Dental® develops and markets a cloud-based dental practice management system titled Curve Hero™. Using a Mac or PC platform, a dental practice can use Curve Hero™ to manage all aspects of their practice, from scheduling to charting to billing, or from front desk to operatory. The application provides for secure and redundant management of all patient records and patient communications. Additionally, when utilizing Curve Dental’s® Curve Image™, the practice can also capture digital images directly to the cloud. Curve Hero™ CURVE DENTAL LTD
5 D835CODX1 10 Dental surgery treatment planning software coDiagnostiX DENTAL WINGS GMBH
6 D835CODX1 10 Dental surgery treatment planning software coDiagnostiX DENTAL WINGS GMBH
7 D835CDX1 9 Dental implant planning software coDiagnostiX DENTAL WINGS GMBH
8 D804W09000460 ACTEON IMAGING SUITE W0900046 Acteon Imaging Suite software program is an application software for general den Acteon Imaging Suite software program is an application software for general dental and maxillofacial diagnostic imaging. Itcontrols exam retrieval, display, enhancement, and saving of digital images from various digital imagingsystems. It stores and communicates these images within the system or across computer systems atdistributed locations. Acteon Imaging Suite DE GOTZEN SRL
9 D8049902630 ACTEON IMAGING SUITE (DVD): 990263 Acteon Imaging Suite software program is an application software for general den Acteon Imaging Suite software program is an application software for general dental and maxillofacial diagnostic imaging. Itcontrols exam retrieval, display, enhancement, and saving of digital images from various digital imagingsystems. It stores and communicates these images within the system or across computer systems atdistributed locations. It is distributed on DVD Acteon Imaging Suite DE GOTZEN SRL
10 00818913020257 AC-UPGRADE AC-UPGRADE Upgrade to Certus 140-2.45GHz Ablation Confirmation NEUWAVE NEUWAVE MEDICAL, INC.
11 00817886020462 5.33 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
12 00817886020455 5.32 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
13 00817886020448 5.31 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
14 00817886020431 5.30 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
15 00817886020424 5.29 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
16 00817886020417 5.28 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
17 00817886020400 5.27 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
18 00817886020394 5.26 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
19 00817886020387 5.25 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
20 00817886020370 5.24 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
21 00817886020363 5.23 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
22 00817886020356 5.22 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
23 00817886020349 5.21 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
24 00817886020332 5.20 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
25 00817886020325 5.19 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
26 00817886020318 5.18 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
27 00817886020301 5.17 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
28 00817886020295 5.16 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
29 00817886020288 5.15 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
30 00817886020271 5.14 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
31 00817886020264 5.13 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
32 00817886020257 5.12 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
33 00817886020240 5.11 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
34 00817886020233 5.10 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
35 00817886020226 5.9 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
36 00817886020219 5.8 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
37 00817886020202 5.7 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
38 00817886020196 5.6 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
39 00817886020189 5.4 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
40 00817886020172 5.3 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
41 00817886020158 5.2 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
42 00817886020141 5.1 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
43 00817886020134 5.0 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
44 00817886020127 4.37 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
45 00817886020110 4.35 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
46 00817886020097 4.0.32 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
47 00817886020080 4.0.31 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
48 00817886020073 4.0.30 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
49 00817886020066 4.0.29 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.
50 00817886020059 4.0.27 The Medstrat Joints system is intended to enable the communication, storage, vie The Medstrat Joints system is intended to enable the communication, storage, viewing, and manipulation of diagnostic medical images and data. The Joints system can show images on workstations locally and/or across computer networks at widely distributed locations. The Joints software is intended for assisting healthcare professionals in preoperative planning and postoperative evaluation of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and positioning the templates. The typical Joints users are trained professionals such as orthopedic surgeons, referring and collaborating physicians, and authorized medical professionals.It is the user's responsibility to bear in mind the display monitor's quality, ambient light conditions, and the tradeoff between image compression ratio and clinical effectiveness for specific image study indications. Joints MEDSTRAT, INC.