Other products from "BAYLIS MÉDICALE CIE INC"
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00685447003670 VXS85-35-81-37-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
2 00685447003717 VXS85-35-81-135-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
3 00685447003700 VXS85-35-81-90-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
4 00685447003694 VXS85-35-81-55-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
5 00685447003687 VXS85-35-81-45-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
6 00685447000891 RFP-103 DSA Cable, Transducer And Electrode, Patient, (Including Connector) 2 BMC Connector Cable
7 00685447000884 RFP-102 DSA Cable, Transducer And Electrode, Patient, (Including Connector) 2 BMC Connector Cable
8 00685447000853 TSK85-32-BD-71L SureFlex Steerable Sheath; Transseptal Dilator; J-Tip Guidewire DYB Introducer, Catheter 2 SureFlex Steerable Guiding Sheath
9 00685447000839 TSK85-32-BD-71S SureFlex Steerable Sheath; Transseptal Dilator; J-Tip Guidewire DYB Introducer, Catheter 2 SureFlex Steerable Guiding Sheath
10 00685447001966 PSZ-300-200 HRX Arthroscope 2 AnchorAccess Track Dilator, 19 mm
11 00685447001935 PSZ-200-400 HRX Arthroscope 2 AnchorAccess Cobb Elevator, 19 mm, Blade
12 00685447001898 PSZ-200-300 HRX Arthroscope 2 Anchor Handle, Retractor
13 00685447001812 PSZ-200-204 HRX Arthroscope 2 AnchorEntry Retractor, Double Flange, 50 mm
14 00685447002109 PSZ-400-307 HRX Arthroscope 2 Anchor 20 Deg Oval End Gouge, 3x5mm
15 00685447000877 RFP-101 DSA Cable, Transducer And Electrode, Patient, (Including Connector) 2 BMC Connector Cable
16 00685447010470 TSK0011 SureFlex Steerable Sheath; Transseptal Dilator; J-Tip Guidewire DYB Introducer, Catheter 2 SureFlex Steerable Guiding Sheath
17 00685447010463 TSK0009 SureFlex Steerable Sheath; Transseptal Dilator; J-Tip Guidewire DYB Introducer, Catheter 2 SureFlex Steerable Guiding Sheath
18 00685447010456 TSK0007 SureFlex Steerable Sheath; Transseptal Dilator; J-Tip Guidewire DYB Introducer, Catheter 2 SureFlex Steerable Guiding Sheath
19 00685447002062 PSZ-400-301 HRX Arthroscope 2 Anchor Curved Tip Ball Probe, 1.7 mm Dia
20 00685447005797 TSK85-32-BD-71S NA SureFlex Steerable Sheath; Transseptal Dilator; J-Tip Guidewire DYB Introducer, Catheter 2 SureFlex Steerable Guiding Sheath
21 00685447005810 TSK85-32-BD-71L NA SureFlex Steerable Sheath; Transseptal Dilator; J-Tip Guidewire DYB Introducer, Catheter 2 SureFlex Steerable Guiding Sheath
22 00685447005803 TSK85-32-BD-71M NA SureFlex Steerable Sheath; Transseptal Dilator; J-Tip Guidewire DYB Introducer, Catheter 2 SureFlex Steerable Guiding Sheath
23 00685447004639 RFP-102 DSA Cable, Transducer And Electrode, Patient, (Including Connector) 2 BMC Connector Cable
24 00685447005667 TSK0006 NA SureFlex Steerable Sheath; Transseptal Dilator; J-Tip Guidewire DYB Introducer, Catheter 2 SureFlex Steerable Guiding Sheath
25 00685447005650 TSK0005 NA SureFlex Steerable Sheath; Transseptal Dilator; J-Tip Guidewire DYB Introducer, Catheter 2 SureFlex Steerable Guiding Sheath
26 00685447005643 TSK0004 NA SureFlex Steerable Sheath; Transseptal Dilator; J-Tip Guidewire DYB Introducer, Catheter 2 SureFlex Steerable Guiding Sheath
27 00685447004608 TSK85-32-BD-71S SureFlex Steerable Sheath; Transseptal Dilator; J-Tip Guidewire DYB Introducer, Catheter 2 SureFlex Steerable Guiding Sheath
28 00685447004622 TSK85-32-BD-71L SureFlex Steerable Sheath; Transseptal Dilator; J-Tip Guidewire DYB Introducer, Catheter 2 SureFlex Steerable Guiding Sheath
29 00685447004615 TSK85-32-BD-71M SureFlex Steerable Sheath; Transseptal Dilator; J-Tip Guidewire DYB Introducer, Catheter 2 SureFlex Steerable Guiding Sheath
30 00685447003663 VXS8-35-81-135-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
31 00685447003656 VXS8-35-81-90-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
32 00685447003649 VXS8-35-81-55-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
33 00685447003632 VXS8-35-81-45-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
34 00685447003625 VXS8-35-81-37-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
35 00685447003618 VXS85-35-63-135-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
36 00685447003601 VXS85-35-63-90-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
37 00685447003595 VXS85-35-63-55-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
38 00685447003588 VXS85-35-63-45-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
39 00685447003571 VXS85-35-63-37-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
40 00685447003564 VXS8-35-63-135-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
41 00685447003540 VXS8-35-63-55-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
42 00685447003533 VXS8-35-63-45-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
43 00685447003526 VXS8-35-63-37-D1 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
44 00685447003519 VXS85-35-81-135-D0 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
45 00685447003502 VXS85-35-81-90-D0 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
46 00685447003496 VXS85-35-81-55-D0 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
47 00685447003489 VXS85-35-81-45-D0 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
48 00685447003472 VXS85-35-81-37-D0 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
49 00685447003465 VXS8-35-81-135-D0 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
50 00685447003458 VXS8-35-81-90-D0 1 x VersaCross Transseptal Sheath; 1 x VersaCross Transseptal Dilator; 1 x J-Tip Guidewire DYB Introducer, Catheter 2 VersaCross Transseptal Sheath
Other products with the same Product Code "DYB"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 06936733740927 RS070518S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
2 06936733740910 RS061118S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
3 06936733740903 RS060725S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
4 06936733740897 RS060721S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
5 06936733740880 RS060718S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
6 06936733740873 RS060518S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
7 06936733740866 RS051118S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
8 06936733740859 RS050725S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
9 06936733740842 RS050721S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
10 06936733740835 RS050718S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
11 06936733740828 RS050518S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
12 06936733740811 RS041118S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
13 06936733740804 RS040725S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
14 06936733740798 RS040721S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
15 06936733740781 RS040718S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
16 06936733740774 RS040518S-II The Puncture Needle incorporates a lumen, which provides a conduit for the inser The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling thewire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
17 06936733740194 RS071118S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
18 06936733740187 RS070718S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
19 06936733740170 RS070518S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
20 06936733740163 RS061118S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
21 06936733740156 RS060725S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
22 06936733740149 RS060721S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
23 06936733740132 RS060718S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
24 06936733740125 RS060518S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
25 06936733740118 RS051118S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
26 06936733740101 RS050725S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
27 06936733740002 RS050721S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
28 06936733739990 RS050718S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
29 06936733739983 RS050518S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
30 06936733739976 RS041118S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
31 06936733739969 RS040725S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
32 06936733739952 RS040721S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
33 06936733739945 RS040718S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
34 06936733739938 RS040518S The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopy and provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
35 06936733739877 RS061118 The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
36 06936733739860 RS051118 The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
37 06936733739853 RS041118 The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
38 06936733738047 CS070718 The puncture needle or an intravascular catheter incorporates a lumen, which pro The puncture needle or an intravascular catheter incorporates a lumen, which provides a conduit for the insertion of the guide wire into the vascular system. The various types of guide wires, model dependent, are utilized as a guiding mechanism for the insertion of the introduction sheath into the vascular system. The guide wire contains a wire collimator, which assists in funneling the wire through the lumen of the puncture needle or the intravascular catheter and contains marking that are visible under fluoroscopy, which can determine the length of the guide wire within the vascular system. The sheath introducer provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vasculature. The main components of the sheath introducer assembly are a hydrophilic coated sheathintroducer, hemostasis valve housing, and a side port with tubing connected to a 3-way stopcock/valve. The hydrophilic coated dilator is used to provide support and stability to the sheath introducer during deployment into the vascular system. The proximal end of the dilator includes a luer port and has a tapered, atraumatic distal tip. Both the sheath and dilator contain bismuth, making these devices visible under fluoroscopy. Brilliant LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
39 06936733737576 FS081135 The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to providesupport and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
40 06936733737552 FS071135 The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to providesupport and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
41 06936733737538 FS061135 The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to providesupport and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
42 06936733737514 FS051135 The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to providesupport and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
43 06936733737484 RS071118 The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to providesupport and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
44 06936733737378 RS070525 The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
45 06936733737361 RS070521 The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
46 06936733737354 RS070518 "The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a "The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
47 06936733737347 RS060525 "The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a "The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
48 06936733737330 RS060521 "The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a "The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
49 06936733737323 RS060518 "The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a "The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.
50 06936733737316 RS050525 "The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a "The ShoocinTM Introducer Kit consists of a puncture needle, a guide wire with a guide wire collimator, a sheath introducer, and a dilator. The Puncture Needle incorporates a lumen, which provides a conduit for the insertion of the Guide Wire into the vascular system. The flexible stainless-steel guide wire is utilized as a guiding mechanism for the insertion of the Introducer Sheath into the vascular system. The Guide Wire contains a wire collimator, which assists in funneling the wire through the lumen of the Puncture Needle. The Guide Wire is radio-detective under fluoroscopy. The Sheath Introducer contains Barium sulfate (BaSO4), making the device visible under fluoroscopyand provides a conduit for introducing other interventional devices, including guide wires and interventional catheters, into the vascular system. The main components of this assembly are a non-hydrophilic coated Sheath Introducer, hemostasis valve housing, and a side port tubing with a 3-way stopcock/valve. The Dilator is used to provide support and stability to the Sheath Introducer during deployment into the vascular system. The proximal end of the Dilator includes a luer port and has a tapered, atraumatic distal tip. There is no radiocontrast agent on the dilator. Shoocin LEPU MEDICAL TECHNOLOGY (BEIJING) CO.,LTD.