Other products from "MEDTRONIC PS MEDICAL, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00643169474932 91101 CATHETER 91101 VENTRICULAR ANTIMICROBIAL JXG Shunt, central nervous system and components 2 ARES™
2 00643169010697 46856 ASSY 46856 FP-STRATA 2 SHUNT SML JXG Shunt, central nervous system and components 2 Strata®
3 00613994804631 42856 VALVE 42856 FP-STRATA 2 SMALL JXG Shunt, central nervous system and components 2 Strata®
4 00643169975958 46856 ASSY 46856 FP-STRATA 2 SHUNT SML JXG Shunt, central nervous system and components 2 Strata™
5 00763000030155 44000 INLET 44000 VENTRICULAR PORT BOTTOM LKG Port & catheter, implanted, subcutaneous, intraventricular 2 N/A
6 00763000030100 27740 SHUNT 27740 STRATA NSC SNAP REG 120CM JXG Shunt, central nervous system and components 2 Strata®
7 00763000027490 46866 ASSY 46866 FP-STRATA 2 SHUNT REG JXG Shunt, central nervous system and components 2 Strata®
8 00885074204574 45807 CARD 45807 SMART STRATA JXG Shunt, central nervous system and components 2 Strata®
9 00763000624743 46911 BAG 46911 DRAINAGE DEHP-FREE 1PK GWM,JXG Device, monitoring, intracranial pressure,Shunt, central nervous system and components 2 Duet®
10 00763000428778 46916 EDMS 46916 DUET BLUECORE WITH VCATH JXG,GWM,PCB Shunt, central nervous system and components,Device, monitoring, intracranial pr Shunt, central nervous system and components,Device, monitoring, intracranial pressure,External cerebrospinal fluid (CSF) diversion 2 Duet®
11 00763000406097 27304 KIT 27304 EDM LUMBAR DRAINAGE CLOSED GWN,GWM,JXG NYSTAGMOGRAPH,Device, monitoring, intracranial pressure,Shunt, central nervous s NYSTAGMOGRAPH,Device, monitoring, intracranial pressure,Shunt, central nervous system and components 2 N/A
12 00763000395995 27703 EDM CATH 27703 NUM LENGTH MARK 35CM GWM,JXG Device, monitoring, intracranial pressure,Shunt, central nervous system and components 2 N/A
13 00763000395988 27303 EDM LUMBAR 27303 DRAIN KIT OPEN TIP JXG,GWM Shunt, central nervous system and components,Device, monitoring, intracranial pressure 2 N/A
14 00763000343217 27304 KIT 27304 EDM LUMBAR DRAINAGE CLOSED JXG,GWM Shunt, central nervous system and components,Device, monitoring, intracranial pressure 2 N/A
15 00763000333546 27673 KIT 27673 EXACTA W/EDM VCATH BIOGL 35CM JXG,GWM Shunt, central nervous system and components,Device, monitoring, intracranial pressure 2 Exacta™
16 00763000333423 24146 EDMS 24146 BECKER NO Y-SITE GWM,JXG Device, monitoring, intracranial pressure,Shunt, central nervous system and components 2 Becker®
17 00763000169893 46918 EDMS 46918 CLEAR-SITE LASER LEVEL JXG,GWM Shunt, central nervous system and components,Device, monitoring, intracranial pressure 2 Clear-Site®
18 00763000169886 27613 LASER 27613 EXACTA W/SCREW ASSY JXG,GWM Shunt, central nervous system and components,Device, monitoring, intracranial pressure 2 Laser Level
19 00763000063979 PM800N-R MOTOR PM800N-R MR8 PNEUM NAVIGATED RFRB HAW Neurological stereotaxic Instrument 2 MR8 Stealth-Midas
20 00763000063962 PM800-R MOTOR PM800-R MR8 PNEUMATIC REFURB ERL,HBB DRILL, SURGICAL, ENT (ELECTRIC OR PNEUMATIC) INCLUDING HANDPIECE,MOTOR, DRILL, PNEUMATIC 2 Midas Rex MR8
21 00763000063818 MR8-AVA12DK-R ATT MR8-AVA12DK-R MR8 12CM VRBL AG DKRFB HBE DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED) 2 Midas Rex MR8
22 00763000029494 5005 E CATH 5005 E VENT RT ANGLE STD 5CM JXG Shunt, central nervous system and components 2 N/A
23 00763000063726 MR8-AT10ADK-R ATT MR8-AT10ADK-R MR8 TEL BSE ANG DK RFB HBE DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED) 2 Midas Rex MR8
24 00763000029067 44211 KIT 44211 VENTRICULOSTOMY RES 6MM SHW JXG Shunt, central nervous system and components 2 N/A
25 00763000029005 96665 SHUNT 96665 STRATA NSC ASSY REG BIOGLIDE JXG Shunt, central nervous system and components 2 Strata®
26 00763000063450 MR8-AA14DK-R ATT MR8-AA14DK-R MR8 14CM ANG DK3.2MMRFB HBE DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED) 2 Midas Rex MR8
27 00763000063405 MR8-AA10-R ATT MR8-AA10-R MR8 10CM ANGLD 2.4MM RFRB HBE DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED) 2 Midas Rex MR8
28 00763000028534 41408 CATHETER 41408 CSF-VENT STD W/SNAP 8CM LKG Port & catheter, implanted, subcutaneous, intraventricular 2 N/A
29 00763000031398 46837 SHUNT 46837 STRATA II BURR HOLE JXG Shunt, central nervous system and components 2 Strata®
30 00763000031381 46636 SHUNT 46636 STRATA NSC BURR JXG Shunt, central nervous system and components 2 Strata®
31 00763000031275 27186 NEEDLE 27186 TUOHY 14-GAUGE 12CM JXG Shunt, central nervous system and components 2 N/A
32 00763000031268 48405 PASSER 48405 CATH V/P SUBCUT 60CM GYK Instrument, shunt system implantation 1 N/A
33 00763000031237 42836 VALVE 42836 STRATA II BURR HOLE JXG Shunt, central nervous system and components 2 Strata™
34 00763000031084 9013 A RESERVOIR 9013 A VENT 12MM CONVT IC 50MM JXG Shunt, central nervous system and components 2 N/A
35 00763000030599 24106 E RES 24106 E NEONATE ANGUL CATH 7CM JXG Shunt, central nervous system and components 2 N/A
36 00763000030445 22101 C RES 22101 C NEO FLAT DOME W/ 2.5CM VCATH JXG Shunt, central nervous system and components 2 N/A
37 00763000030308 43551 CATH 43551 C/P STD PLIANT BAR IMP JXG Shunt, central nervous system and components 2 N/A
38 00763000030285 44105 RESERVOIR 44105 B/INLET VENT. CONV LKG Port & catheter, implanted, subcutaneous, intraventricular 2 N/A
39 00763000428747 46913 EDMS 46913 DUET INTERLINK SITES PCB,GWM,JXG External cerebrospinal fluid (CSF) diversion,Device, monitoring, intracranial pr External cerebrospinal fluid (CSF) diversion,Device, monitoring, intracranial pressure,Shunt, central nervous system and components 2 Duet®
40 00885074278896 27831 SHUNT 27831 SNAP STRATA II REG BLUNT P/C JXG Shunt, central nervous system and components 2 Strata®
41 00673978248660 5005 I CATH 5005 I VENT RIGHT ANGLE 8CM JXG Shunt, central nervous system and components 2 NA
42 00643169975897 44465 VALVE 44465 STRATA NSC LP JXG Shunt, central nervous system and components 2 Strata™
43 00643169507494 3008 A CLIP 3008 A RIGHT ANGLE SMALL JXG Shunt, central nervous system and components 2 NA
44 00643169497535 24106 B RES 24106 B NEONATE R/A V-CATH 4CM IMP JXG Shunt, central nervous system and components 2 NA
45 00613994965547 27211 CATH 27211 VENT SLOTTED 16CM JXG Shunt, central nervous system and components 2 NA
46 00763000030124 27695 CATH 27695 EDM VENT TRANS W/STRIPE 35CM JXG Shunt, central nervous system and components 2 N/A
47 00763000030018 41103 CATH 41103 CSF-VENT STANDARD PLIANT JXG Shunt, central nervous system and components 2 N/A
48 00885074228273 018051 SCREW 018051 CRUCIATE RESCUE 1.8X5MM 1 HWC Screw, fixation, bone 2 TiMesh®
49 00885074228266 018031 SCREW 018031 CRUCIATE RESCUE 1.8X3MM 1 HWC Screw, fixation, bone 2 TiMesh®
50 00763000029630 23067 ADAPTER 23067 PREIMPLANT TEST SNAP ASSY LKG Port & catheter, implanted, subcutaneous, intraventricular 2 N/A
Other products with the same Product Codes "LKG, JXG"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 10381780374121 SP0220 The AccuDrain™ External CSF Drainage System is used to drain cerebrospinal fluid The AccuDrain™ External CSF Drainage System is used to drain cerebrospinal fluid (CSF) from the ventricles of the brain or the lumbar subarachnoid space to a drainage bag. System components facilitate CSF drainage, CSF sampling and intracranial pressure (ICP) monitoring. Monitoring of intracranial pressure (ICP) is usually performed in selected patients with severe head injury, subarachnoid hemorrhage, Reyes syndrome or similar encephalopathies, hydrocephalus, hydrocephalic shunt infections, intracranial hemorrhage and pre and/or post-operative monitoring. AccuDrain® INTEGRA LIFESCIENCES CORPORATION
2 10381780356158 NL8504121 NL8504121 The Integra Essential Shunt Kit-Flat Bottom Design is designed to deliver CSF fr The Integra Essential Shunt Kit-Flat Bottom Design is designed to deliver CSF from the ventricles of the brain to the peritoneal cavity. Each kit contains one CSF flushing reservoir with attached 120cm kink-resistant striped peritoneal tubing. The CSF flow control valve is located inside the peritoneal tubing immediately distal to the reservoir. One 18cm ventricular catheter with stylet and one right-angle ventricular catheter guide are also included. Integra Essential Shunt Kit Flat Bottom Design INTEGRA LIFESCIENCES CORPORATION
3 10381780356141 NL8504120 NL8504120 The Integra Essential Shunt Kit-Flat Bottom Design is designed to deliver CSF fr The Integra Essential Shunt Kit-Flat Bottom Design is designed to deliver CSF from the ventricles of the brain to the peritoneal cavity. Each kit contains one CSF flushing reservoir with attached 120cm kink-resistant striped peritoneal tubing. The CSF flow control valve is located inside the peritoneal tubing immediately distal to the reservoir. One 18cm ventricular catheter with stylet and one right-angle ventricular catheter guide are also included. Integra Essential Shunt Kit Flat Bottom Design INTEGRA LIFESCIENCES CORPORATION
4 10381780356134 NL8504112 NL8504112 HS ESSENTIAL CSF SHUNT SYSTEMThe Integra Essential Shunt Kit- Burr Hole Design c HS ESSENTIAL CSF SHUNT SYSTEMThe Integra Essential Shunt Kit- Burr Hole Design contains one 16mm CSF Flow Control Valve, one 18cm Ventricular Catheter with stylet and one 120cm open-ended peritoneal catheter. The CSF flow control valve, designed for placement in a formal burr hole, is a spherically shaped, silicone elastomer device used for the treatment of hydrocephalic patients when shunting cerebrospinal fluid (CSF) from the ventricles of the brain. The valve incorporates an internal high pressure diaphragm for proximal control of CSF flow. The device also provides one-way flow control. The kit is designed to deliver CSF from the ventricles of the brain to the peritoneal cavity. Integra Essential Shunt Kit INTEGRA LIFESCIENCES CORPORATION
5 10381780356127 NL8504111 NL8504111 HS ESSENTIAL CSF SHUNT SYSTEMThe Integra Essential Shunt Kit- Burr Hole Design c HS ESSENTIAL CSF SHUNT SYSTEMThe Integra Essential Shunt Kit- Burr Hole Design contains one 16mm CSF Flow Control Valve, one 18cm Ventricular Catheter with stylet and one 120cm open-ended peritoneal catheter. The CSF flow control valve, designed for placement in a formal burr hole, is a spherically shaped, silicone elastomer device used for the treatment of hydrocephalic patients when shunting cerebrospinal fluid (CSF) from the ventricles of the brain. The valve incorporates an internal medium pressure diaphragm for proximal control of CSF flow. The device also provides one-way flow control. The kit is designed to deliver CSF from the ventricles of the brain to the peritoneal cavity. Integra Essential Shunt Kit INTEGRA LIFESCIENCES CORPORATION
6 10381780356110 NL8504110 NL8504110 HS ESSENTIAL CSF SHUNT SYSTEMThe Integra Essential Shunt Kit- Burr Hole Design c HS ESSENTIAL CSF SHUNT SYSTEMThe Integra Essential Shunt Kit- Burr Hole Design contains one 16mm CSF Flow Control Valve, one 18cm Ventricular Catheter with stylet and one 120cm open-ended peritoneal catheter. The CSF flow control valve, designed for placement in a formal burr hole, is a spherically shaped, silicone elastomer device used for the treatment of hydrocephalic patients when shunting cerebrospinal fluid (CSF) from the ventricles of the brain. The valve incorporates an internal low pressure diaphragm for proximal control of CSF flow. The device also provides one-way flow control. The kit is designed to deliver CSF from the ventricles of the brain to the peritoneal cavity. Integra Essential Shunt Kit INTEGRA LIFESCIENCES CORPORATION
7 10381780211082 NL850500V NL850500V Integra™ Ventricular Drainage System provides a sterile path for the drainage of Integra™ Ventricular Drainage System provides a sterile path for the drainage of cerebrospinal fluid (CSF) from an intraventricular catheter to a collection bag. The system can be used for external drainage, and the management of hydrocephalic shunt infections, or treatment of other cerebral conditions such as pre-operative or post-operative pressure monitoring of CSF to control increased intracranial pressure. N/A INTEGRA LIFESCIENCES CORPORATION
8 10381780112273 NL79034S02 NL79034S02 The silicone elastomer Integra CSF Reservoir, in connection with a ventricular c The silicone elastomer Integra CSF Reservoir, in connection with a ventricular catheter, is designed to provide access to the brain and/or CSF. The Convertible model incorporates an outlet tube in addition to an inlet tube. The outlet tube may be connected to a distal catheter, allowing the reservoir to be used in a shunting system, if later indicated. The 2.5cm base diameter reservoir is a flat bottom design; the 1.5cm base diameter reservoir is a burr-hole model. Dual Outlet Convertible Integra™ Reservoir INTEGRA LIFESCIENCES CORPORATION
9 10381780112266 INS410MM INS410MM The Evolution Pole Mount Assembly provides support and alignment for the Externa The Evolution Pole Mount Assembly provides support and alignment for the External CSF Drainage and Monitoring Systems. These systems are used for draining CSF from an intraventricular or lumbar catheter to an external CSF drainage system. This Integra Pole Mount is provided with a laser leveling device and an optional line level. The laser level is attached via a bracket. LimiTorr™ INTEGRA LIFESCIENCES CORPORATION
10 10381780112259 INS410CM INS410CM The Evolution Pole Mount Assembly provides support and alignment for the Externa The Evolution Pole Mount Assembly provides support and alignment for the External CSF Drainage and Monitoring Systems. These systems are used for draining CSF from an intraventricular or lumbar catheter to an external CSF drainage system. This Integra Pole Mount is provided with a laser leveling device and an optional line level. The laser level is attached via a bracket. LimiTorr™ INTEGRA LIFESCIENCES CORPORATION
11 10381780112242 INS410 INS410 The Evolution Pole Mount Assembly provides support and alignment for the Externa The Evolution Pole Mount Assembly provides support and alignment for the External CSF Drainage and Monitoring Systems. These systems are used for draining CSF from an intraventricular or lumbar catheter to an external CSF drainage system. This Integra Pole Mount is provided with a laser leveling device and an optional line level. The laser level is attached via a bracket. LimiTorr™ INTEGRA LIFESCIENCES CORPORATION
12 10381780112228 INS400L INS400L The Pole Mount Laser Level device is provided with mounting bracket for use with The Pole Mount Laser Level device is provided with mounting bracket for use with Integra Pole Mount Assemblies. The Pole Mount Laser provides alignment for the External CSF Drainage and Monitoring Systems. These systems are used for draining CSF from an intraventricular catheter or lumbar catheter to an external ventricular drainage system. LimiTorr™ INTEGRA LIFESCIENCES CORPORATION
13 10381780112211 INS400CM INS400CM The Evolution Pole Mount Assembly provides support and alignment for the Externa The Evolution Pole Mount Assembly provides support and alignment for the External CSF Drainage and Monitoring Systems. These systems are used for draining CSF from an intraventricular or lumbar catheter to an external CSF drainage system. This Integra Pole Mount is provided with a laser leveling device and an optional line level. The laser level is attached via a bracket. LimiTorr™ INTEGRA LIFESCIENCES CORPORATION
14 10381780112204 INS400 INS400 The Evolution Pole Mount Assembly provides support and alignment for the Externa The Evolution Pole Mount Assembly provides support and alignment for the External CSF Drainage and Monitoring Systems. These systems are used for draining CSF from an intraventricular or lumbar catheter to an external CSF drainage system. This Integra Pole Mount is provided with a laser leveling device and an optional line level. The laser level is attached via a bracket. LimiTorr™ INTEGRA LIFESCIENCES CORPORATION
15 10381780112198 INS310 INS310 MoniTorr ICP Pole Mount Assembly with cm H2O and mm Hg Rail: The Pole Mount Asse MoniTorr ICP Pole Mount Assembly with cm H2O and mm Hg Rail: The Pole Mount Assembly provides support and alignment for the External CSF Drainage and Monitoring Systems (EVD). These systems are used for draining CSF from an intraventricular catheter to the external ventricular drainage system. A Pole Mount Sliding Bracket is supplied with each Pole Mount Assembly. The Pole Mount Sliding Bracket is used to secure the EVD system to the rail on the Pole Mount Assembly. Integra™ MoniTorr ICP™ Pole Mount Assmbly INTEGRA LIFESCIENCES CORPORATION
16 10381780112181 INS305 INS-305 The MoniTorr ICP Pole Mount Assembly with cm H2O and mm Hg Rail provides support The MoniTorr ICP Pole Mount Assembly with cm H2O and mm Hg Rail provides support and alignment for External Ventricular Drainage (EVD) Systems. These systems are used for draining cerebrospinal fluid (CSF) from an intraventricular catheter to the external ventricular drainage system. Integra™ INTEGRA LIFESCIENCES CORPORATION
17 10381780112174 INS301 INS301 The Integra Pole Mount Sliding Bracket can be used with Integra External Ventric The Integra Pole Mount Sliding Bracket can be used with Integra External Ventricular Drainage (EVD) systems and may also be used as a replacement assembly or accessory component. The Integra Pole Mount Sliding Bracket is used to secure the EVD system to the rail of the Pole Mount Assembly. Integra™ Pole Mount Sliding Bracket INTEGRA LIFESCIENCES CORPORATION
18 10381780112167 INS300L INS300L MoniTorr ICP Pole Mount Assembly with cm H2O and mm Hg Rail and Laser Leveling D MoniTorr ICP Pole Mount Assembly with cm H2O and mm Hg Rail and Laser Leveling Device: The Pole Mount Assembly provides support and alignment for the External CSF Drainage and Monitoring Systems (EVD). These systems are used for draining CSF from an intraventricular catheter to the external ventricular drainage system. A Pole Mount Sliding Bracket is supplied with each Pole Mount Assembly. The Pole Mount Sliding Bracket is used to secure the EVD system to the rail on the Pole Mount Assembly. Integra™ MoniTorr ICP™ Pole Mount Assmbly INTEGRA LIFESCIENCES CORPORATION
19 10381780112143 INS300 INS300 MoniTorr ICP Pole Mount Assembly with cm H2O and mm Hg rail: The Pole Mount Asse MoniTorr ICP Pole Mount Assembly with cm H2O and mm Hg rail: The Pole Mount Assembly provides support and alignment for the External CSF Drainage and Monitoring Systems (EVD). These systems are used for draining CSF from an intraventricular catheter to the external ventricular drainage system. A Pole Mount Sliding Bracket is supplied with each Pole Mount Assembly. The Pole Mount Sliding Bracket is used to secure the EVD system to the rail on the Pole Mount Assembly. Integra™ MoniTorr ICP™ Pole Mount Assmbly INTEGRA LIFESCIENCES CORPORATION
20 10381780112136 310991 310991 POLE MOUNT PARTS KIT ASSEMBLYPole Mount Spare Parts Kit Integra™ Pole Mount Spare Parts Kit INTEGRA LIFESCIENCES CORPORATION
21 10381780072560 SP0236 SP0236 MONITORR SPECIAL NEEDLE SITEThe MoniTorr ICP External CSF Drainage and Monitorin MONITORR SPECIAL NEEDLE SITEThe MoniTorr ICP External CSF Drainage and Monitoring System provides a simple to use, closed system for the drainage of cerebrospinal fluid (CSF) from ventricles of the brain or the lumbar subarachnoid space to a drainage bag. The system may be used with a pole mounted assembly that allows for simple, quick, and accurate alignment with the patient and secure, positive or negative pressure level setting. The system has also been designed to provide for ease of patient transport through a compact design and an antimicrobial hydrophobic vent feature that resists occlusion. Common features include a calibrated graduated burette, a drainage bag, sampling/aspiration sites, green stripe pressure tubing, and a needle Y injection site. MoniTorr™ INTEGRA LIFESCIENCES CORPORATION
22 10381780072553 SP0224 SP0224 LUMBAR CATHETER CLOSED TIPThe 80cm barium impregnated silicone lumbar catheter h LUMBAR CATHETER CLOSED TIPThe 80cm barium impregnated silicone lumbar catheter has a closed radiopaque tip and is supplied with a Teflon coated stainless steel guide wire and end stop for assisting catheter placement. Approximately 18mm of the tip is multi-perforated to help improve flow and decrease the possibility of obstruction. Designed for diverting fluid from the lumbar subarachnoid space, the catheter can be inserted with a Tuohy needle using percutaneous techniques. The external portion of the catheter is secured to the subcutaneous tissue in the lumbar area by the suture collar. A 14-guage thin wall Tuohy needle with obturator, guide wire, and 22-gauge blunt needle are included. A female luer adapter and train relief tubing is also included. Two suture collars may be wrapped around the catheter and may be anchored in place with a suture. Hermetic™ External Drainage Lumbar Catheter INTEGRA LIFESCIENCES CORPORATION
23 10381780072546 NL98003S01 NL98003S01 PERITONEAL CATHETER, 90CM LENGTHThe Integra Peritoneal Open-Ended Catheter with PERITONEAL CATHETER, 90CM LENGTHThe Integra Peritoneal Open-Ended Catheter with Slits is designed to deliver cerebrospinal fluid (CSF) to the peritoneal cavity with minimum flow resistance. This catheter is recommended for use with pressure control valves located proximally in the hydrocephalic shunt system. The catheter is made of a high durometer silicone elastomer which helps resist kinking and occlusion caused by the bending or twisting of the catheter. A stripe, made of barium sulfate impregnated silicone elastomer, is imbedded in the wall of the catheter. The stripe provides a catheter which is radiopaque throughout its entire length, while keeping barium sulfate away from the surface of the catheter and allowing visual observation of flow through the catheter during implantation. Black radiopaque length markers are located at 10, 20, and 30 cm from the distal tip to assist in positioning of the catheter. The catheter is open-ended; it does not resist retrograde flow. This catheter provides flow resistance of approximately 12 mm H2O at a flow rate of 23 ml/hr. Integra Peritoneal Open-Ended Catheter With Slits INTEGRA LIFESCIENCES CORPORATION
24 10381780072539 NL97105S01 NL97105S01 LONG SPETZLER 105CM LP SHUNT The Spetzler Lumbar Peritoneal Shunt System is des LONG SPETZLER 105CM LP SHUNT The Spetzler Lumbar Peritoneal Shunt System is designed to shunt cerebrospinal fluid (CSF) from the lumbar subarachnoid space to the peritoneum. Due to the small diameter of the catheter tubing, shunting may be accomplished by percutaneous techniques. A variety of devices are available: a one-piece model without a reservoir; separate large or small reservoirs that contain a one-way valve, which may be used when a flushing capability is required; and a separate miter valve, available in low, medium, or high pressure, which may be used when added resistance is desired. Integra Spetzler™ Lumbar Peritoneal Shunt System INTEGRA LIFESCIENCES CORPORATION
25 10381780072522 NL97003S01 NL97003S01 3 FRENCH T-TUBEThe Integra Edwards-Barbaro Syringo-Peritoneal Shunt is designed 3 FRENCH T-TUBEThe Integra Edwards-Barbaro Syringo-Peritoneal Shunt is designed to provide continuous drainage of fluid from within a spinal cord cyst to a site outside the spinal canal. The T-tube diameter is small to minimize the size of the myelotomy and the catheter is flexible to minimize the spinal cord manipulation necessary to insert the tube into a spinal cord cyst. The T-shape allows drainage above and below the myelotomy site, helps prevent kinking by providing a right-angle exit through the dura, and reduces the risk of migration out of the spinal cord. The multi-holed catheter reduces the risk of clogging at the spinal end of the system. The suture tab allows the T-tube to be anchored to the dura or paraspinous muscles without the risk of shunt occlusion associated with a circumferential ligature. If a step down connector is used, it adapts the T-tube diameter to the peritoneal reflux control catheter. Integra® INTEGRA LIFESCIENCES CORPORATION
26 10381780072515 NL97001S01 NL97001S01 STERILE LUER CONNECTOR N/A INTEGRA LIFESCIENCES CORPORATION
27 10381780072492 NL8509851 NL8509851 MINI LPV II SHUNT KIT, MED.The Integra LPV II Valve Shunt Kits are designed to d MINI LPV II SHUNT KIT, MED.The Integra LPV II Valve Shunt Kits are designed to deliver CSF from the ventricles of the brain to the peritoneal cavity. The kit contains a LPV II valve, mini, a Pudenz Ventricular Catheter and an integral, open-ended kink resistant catheter attached to the outlet of the valve. The kit is available in a medium pressure range. All valves and catheters contain barium sulfate for x-ray detectability. Integra LPV II Valve Shunt Kit INTEGRA LIFESCIENCES CORPORATION
28 10381780072485 NL8509850 NL8509850 STANDARD LPV II SHUNT KIT, MED.The Integra LPV II Valve Shunt Kits are designed STANDARD LPV II SHUNT KIT, MED.The Integra LPV II Valve Shunt Kits are designed to deliver CSF from the ventricles of the brain to the peritoneal cavity. The kit contains a LPV II valve, standard, a Pudenz Ventricular Catheter and an integral, open-ended kink resistant catheter attached to the outlet of the valve. The kit is available in a medium pressure range. All valves and catheters contain barium sulfate for x-ray detectability. Integra LPV II Valve Shunt Kit INTEGRA LIFESCIENCES CORPORATION
29 10381780072454 NL8509831 NL8509831 MINI LPV II VALVE, HIGHThe Integra LVP II Valve, Mini is a silicone elastomer va MINI LPV II VALVE, HIGHThe Integra LVP II Valve, Mini is a silicone elastomer valve used for the treatment of hydrocephalic patients when shunting cerebrospinal fluid (CSF) from the ventricles of the brain. The valve incorporates an internal high pressure valve assembly which is mounted distal to an integral pumping reservoir for proximal control of CSF flow. The device also provides one-way flow control. Integral occluders are incorporated on the proximal and distal end of the valve to allow manual control of flushing or pumping of CSF proximally or distally. The device is fitted with a polypropylene needle guard, designed to prevent inadvertent needle puncture through the base of the reservoir during percutaneous injection. The valve contains an integral plastic connector on each end to simplify the assembly procedure. Integra LPV II Valve INTEGRA LIFESCIENCES CORPORATION
30 10381780072447 NL8509821 NL8509821 MINI LPV II VALVE, MED.The Integra LVP II Valve, Mini is a silicone elastomer va MINI LPV II VALVE, MED.The Integra LVP II Valve, Mini is a silicone elastomer valve used for the treatment of hydrocephalic patients when shunting cerebrospinal fluid (CSF) from the ventricles of the brain. The valve incorporates an internal medium pressure valve assembly which is mounted distal to an integral pumping reservoir for proximal control of CSF flow. The device also provides one-way flow control. Integral occluders are incorporated on the proximal and distal end of the valve to allow manual control of flushing or pumping of CSF proximally or distally. The device is fitted with a polypropylene needle guard, designed to prevent inadvertent needle puncture through the base of the reservoir during percutaneous injection. The valve contains an integral plastic connector on each end to simplify the assembly procedure. Integra LPV II Valve INTEGRA LIFESCIENCES CORPORATION
31 10381780072430 NL8509810 NL8509810 STANDARD LPV II VALVE, LOWThe Integra LVP II Valve, Standard is a silicone elast STANDARD LPV II VALVE, LOWThe Integra LVP II Valve, Standard is a silicone elastomer valve used for the treatment of hydrocephalic patients when shunting cerebrospinal fluid (CSF) from the ventricles of the brain. The valve incorporates an internal low pressure valve assembly which is mounted distal to an integral pumping reservoir for proximal control of CSF flow. The device also provides one-way flow control. Integral occluders are incorporated on the proximal and distal end of the valve to allow manual control of flushing or pumping of CSF proximally or distally. The device is fitted with a polypropylene needle guard, designed to prevent inadvertent needle puncture through the base of the reservoir during percutaneous injection. The valve contains an integral plastic connector on each end to simplify the assembly procedure. Integra LPV II Valve INTEGRA LIFESCIENCES CORPORATION
32 10381780072423 NL8508560 NL8508560 Large bore tubing assembly with integral one-way valve. Integra Large Bore Tubing Set INTEGRA LIFESCIENCES CORPORATION
33 10381780072416 NL8508430 NL8508430 LUMBAR CATHETER WITH GUIDE WIREThe 80cm barium impregnated silicone lumbar cathe LUMBAR CATHETER WITH GUIDE WIREThe 80cm barium impregnated silicone lumbar catheter has a closed tip and is supplied with a Teflon coated stainless steel guide wire and end stop for assisting catheter placement. Approximately 18mm of the tip is multi-perforated to help improve flow and decrease the possibility of obstruction. Four tantalum impregnated length markers are placed on the proximal end of the catheter. Designed for diverting fluid from the lumbar subarachnoid space, the catheter can be inserted with a tuohy needle using percutaneous techniques. The first marker aligns with the opening in the hub of the Touhy needle, after which the markers are spaced at 5cm intervals from the first marker to allow the surgeon to gauge the length of catheter that has been implanted into the lumbar subarachnoid space. The external portion of the catheter is secured to the subcutaneous tissue in the lumbar area by the suture collar. Hermetic Lumbar Drainage Accessory Kit INTEGRA LIFESCIENCES CORPORATION
34 10381780072409 NL8508420 NL8508420 TRAUMACATH VENTRICULAR CATHETER SETThe TraumaCath Ventricular Catheter set cathe TRAUMACATH VENTRICULAR CATHETER SETThe TraumaCath Ventricular Catheter set catheter is barium striped. Designed for diverting fluid from the ventricles through a series of drainage holes, the catheter can be inserted into the ventricular cavity with the stainless steel stylet. A trocar is supplied with the catheter to facilitate subcutaneous tunneling away from the burr hole. The external portion of the catheter may be secured to the scalp by the suture tab. The luer lock supplied with each ventricular catheter set will connect the catheter to any Integra external drainage system. TraumaCath Ventricular Catheter Set INTEGRA LIFESCIENCES CORPORATION
35 10381780072393 NL8508330 NL8508330 LUMBAR DRAINAGE KITThe 80cm barium impregnated silicone lumbar catheter has an o LUMBAR DRAINAGE KITThe 80cm barium impregnated silicone lumbar catheter has an open tip and is cut at an angle. Approximately 18mm of the tip is multi-perforated to help improve flow and decrease the possibility of obstruction. Four tantalum impregnated length markers are placed on the proximal end of the catheter. Designed for diverting fluid from the lumbar subarachnoid space, the catheter can be inserted with a tuohy needle using percutaneous techniques. The first marker aligns with the opening in the hub of the Touhy needle, after which the markers are spaced at 5cm intervals from the first marker to allow the surgeon to gauge the length of catheter that has been implanted into the lumbar subarachnoid space. The external portion of the catheter is secured to the subcutaneous tissue in the lumbar area by the suture collar. Hermetic Lumbar Drainage Accessory Kit INTEGRA LIFESCIENCES CORPORATION
36 10381780072386 NL8508220 NL8508220 HERMETIC VENTRICULAR CATHETER SETThe Hermetic Ventricular Catheter set catheter HERMETIC VENTRICULAR CATHETER SETThe Hermetic Ventricular Catheter set catheter is barium impregnated. Designed for diverting fluid from the ventricles through a series of drainage holes, the catheter can be inserted into the ventricular cavity with the stainless steel stylet. A trocar is supplied with the catheter to facilitate subcutaneous tunneling away from the burr hole. The external portion of the catheter may be secured to the scalp by the suture tab. The luer lock supplied with each ventricular catheter set will connect the catheter to any Integra external drainage system. Hermetic™ INTEGRA LIFESCIENCES CORPORATION
37 10381780072355 NL8501519 NL8501519 CATHETER PUDENZ RT ANG. VENT. STRIPEDThe Integra Pudenz Ventricular Catheter is CATHETER PUDENZ RT ANG. VENT. STRIPEDThe Integra Pudenz Ventricular Catheter is designed for shunting cerebrospinal fluid (CSF) from the ventricles of the brain. The catheter is manufactured from a high durometer silicone elastomer, which helps resist kinking and occlusion caused by the bending or twisting of the catheter. A stripe, made of barium sulfate impregnated silicone elastomer is imbedded in the wall of the catheter. The stripe provides a catheter which is radiopaque throughout its entire length, while keeping barium sulfate away from the surface of the catheter and allowing visual observation of flow through the catheter during implantation. The right-angle model is formed with a right-angle bend .The right-angle bend of this model allows the use of a straight, rather than a right-angle, connector to fasten the catheter to a flat-bottom flushing device. A black, radiopaque marker is located at the right-angle bend to allow the surgeon to easily identify the location of the bend during implantation with a stylet. Integra Pudenz Ventricular Catheter INTEGRA LIFESCIENCES CORPORATION
38 10381780072348 NL8501504 NL8501504 The Pudenz Ventricular Catheter is designed for shunting CSF from the ventricles The Pudenz Ventricular Catheter is designed for shunting CSF from the ventricles of the brain. The Graduated Small Model has a slightly smaller outside diameter, and is made of a lower durometer (softer) silicone elastomer. Integra Pudenz Ventricular Catheter INTEGRA LIFESCIENCES CORPORATION
39 10381780072331 NL8501382 NL8501382 CATH PUD PERIT W/G STRIPEDThe silicone elastomer Pudenz Peritoneal Catheter is d CATH PUD PERIT W/G STRIPEDThe silicone elastomer Pudenz Peritoneal Catheter is designed to deliver cerebrospinal fluid (CSF) to the peritoneal cavity through a slit valve near the distal tip. The slit valve consists of four individual slits placed in the catheter wall. The slit valve may be used to control shunt-system closing pressure. It also serves to help resist retrograde flow of fluids into the distal end of the catheter. The closing pressure range is high, which is 95-150 mm of H2O. The graduated model of the Pudenz Peritoneal Catheter is manufactured from a high durometer silicone elastomer, which helps resist kinking and occlusion. The tip of the catheter contains a radiopaque tantalum impregnated, silicone elastomer plug to aid in determining location during and subsequent to implantation. The catheter displays radiopaque markers to allow the surgeon to measure the length of tubing placed within the body during surgery. Integra Pudenz Peritoneal Catheter INTEGRA LIFESCIENCES CORPORATION
40 10381780072324 NL8501381 NL8501381 CATH PUD PERIT W/G STRIPEDThe silicone elastomer Pudenz Peritoneal Catheter is d CATH PUD PERIT W/G STRIPEDThe silicone elastomer Pudenz Peritoneal Catheter is designed to deliver cerebrospinal fluid (CSF) to the peritoneal cavity through a slit valve near the distal tip. The slit valve consists of four individual slits placed in the catheter wall. The slit valve may be used to control shunt-system closing pressure. It also serves to help resist retrograde flow of fluids into the distal end of the catheter. The closing pressure range is medium, which is 55-94 mm of H2O. The graduated model of the Pudenz Peritoneal Catheter is manufactured from a high durometer silicone elastomer, which helps resist kinking and occlusion. The tip of the catheter contains a radiopaque tantalum impregnated, silicone elastomer plug to aid in determining location during and subsequent to implantation. The catheter displays radiopaque markers to allow the surgeon to measure the length of tubing placed within the body during surgery. Integra Pudenz Peritoneal Catheter INTEGRA LIFESCIENCES CORPORATION
41 10381780072317 NL8501380 NL8501380 CATH PUD PERIT W/G STRIPEDThe silicone elastomer Pudenz Peritoneal Catheter is d CATH PUD PERIT W/G STRIPEDThe silicone elastomer Pudenz Peritoneal Catheter is designed to deliver cerebrospinal fluid (CSF) to the peritoneal cavity through a slit valve near the distal tip. The slit valve consists of four individual slits placed in the catheter wall. The slit valve may be used to control shunt-system closing pressure. It also serves to help resist retrograde flow of fluids into the distal end of the catheter. The closing pressure range is low, which is 15-54 mm of H2O. The graduated model of the Pudenz Peritoneal Catheter is manufactured from a high durometer silicone elastomer, which helps resist kinking and occlusion. The tip of the catheter contains a radiopaque tantalum impregnated, silicone elastomer plug to aid in determining location during and subsequent to implantation. The catheter displays radiopaque markers to allow the surgeon to measure the length of tubing placed within the body during surgery. Integra Pudenz Peritoneal Catheter INTEGRA LIFESCIENCES CORPORATION
42 10381780072300 NL8501328 NL8501328 NEUROVIEW ENDOSCOPIC VENT CATHThe Integra Neuroview ventricular catheter is desi NEUROVIEW ENDOSCOPIC VENT CATHThe Integra Neuroview ventricular catheter is designed to be used with a neurosurgical endoscope. The endoscope is used when a physician wishes to place a catheter’s tip at a specific intraventricular location or to view intraventricular anatomy. The slit-tip of the catheter protects the endocscope from debris buildup during insertion, but allows intraventricular viewing to assist in optimal catheter placement. The Neuroview ventricular catheter is manufactured from a high durometer silicone elastomer, which helps resist kinking and occlusion caused by the bending or twisting of the catheter. A stripe, made of barium sulfate impregnated silicone elastomer, is imbedded in the wall of the catheter. The stripe provides a catheter which is radiopaque throughout its entire length, while keeping barium sulfate away from the surface of the catheter and allowing visual observation of flow through the catheter during implantation. The catheter has multiple small perforations near the tip to facilitate drainage of CSF and to help reduce clogging. The extreme tip is closed to help prevent particulate matter from entering the tubing during insertion. The catheter has graduation markers to allow the surgeon to measure the length of tubing placed within the ventricle during surgery. Integra Neuroview Endoscopic Ventricular Catheter INTEGRA LIFESCIENCES CORPORATION
43 10381780072294 NL8501222 NL8501222 The Infant Cardiac Catheter model is designed for ventriculoatrial shunting of C The Infant Cardiac Catheter model is designed for ventriculoatrial shunting of CSF in children with small veins. The distal section of the catheter is reduced to approximately one-half standard diameter for easier insertion. The proximal section of the catheter contains an imbedded barium sulfate-impregnated strip, and the distal section is fully barium sulfate-impregnated. The infant model does not contain graduation markets. Integra Pudenz Infant Cardiac Catheter INTEGRA LIFESCIENCES CORPORATION
44 10381780072287 NL8501221 NL8501221 The Infant Cardiac Catheter model is designed for ventriculoatrial shunting of C The Infant Cardiac Catheter model is designed for ventriculoatrial shunting of CSF in children with small veins. The distal section of the catheter is reduced to approximately one-half standard diameter for easier insertion. The proximal section of the catheter contains an imbedded barium sulfate-impregnated strip, and the distal section is fully barium sulfate-impregnated. The infant model does not contain graduation markets. Integra Pudenz Infant Cardiac Catheter INTEGRA LIFESCIENCES CORPORATION
45 10381780072270 NL8501202 NL8501202 The silicone elastomer Pudenz Cardiac Catheter is designed to deliver CSF to the The silicone elastomer Pudenz Cardiac Catheter is designed to deliver CSF to the right atrium of the heart through a slit valve near the distal tip. The slit valve consists of four individual slits placed in the catheter wall. The slit valve may be used to control shunt-system pressure. It also serves to resist retrograde flow of fluids into the distal end of the catheter. This standard model has a high closing pressure range (95-150 mm H2O). Integra Pudenz Cardiac Catheter INTEGRA LIFESCIENCES CORPORATION
46 10381780072263 NL8501200 NL8501200 The silicone elastomer Pudenz Cardiac Catheter is designed to deliver CSF to the The silicone elastomer Pudenz Cardiac Catheter is designed to deliver CSF to the right atrium of the heart through a slit valve near the distal tip. The slit valve consists of four individual slits placed in the catheter wall. The slit valve may be used to control shunt-system pressure. It also serves to resist retrograde flow of fluids into the distal end of the catheter. This standard model has a medium closing pressure range (55-94 mm H2O). Integra Pudenz Cardiac Catheter INTEGRA LIFESCIENCES CORPORATION
47 10381780072256 NL8500312 NL8500312 VALVE FLUSH F/B D/C W/CONNECTORThe Integra Mishler Dual Chamber Flushing valve, VALVE FLUSH F/B D/C W/CONNECTORThe Integra Mishler Dual Chamber Flushing valve, Flat Bottom Design incorporates two separate interior chambers to provide two-way flow control when shunting cerebrospinal fluid (CSF) from the ventricles of the brain. This silicone elastomer flushing valve is available with or without an integral Anti-Siphon Device. The flat bottom configuration eliminates the need for a formal burr hole, provides greater latitude in positioning the flushing valve and allows the ventricular catheter to be revised without disturbing the flushing valve. Due to the dual chamber feature, the proximal and distal catheters may be flushed separately or simultaneously. The flow of CSF from the ventricular catheter is controlled by a miter valve located on the vertical chamber divider. This valve is designed to open under a medium positive ventricular pressure and close under a negative pressure. The flushing valve dome is marked with an arrow to indicate the CSF flow direction. The flange overlying the skull contains sutural holes to facilitate securing the device to the periosteum. Integra Mishler Dual Chamber Flushing Valve INTEGRA LIFESCIENCES CORPORATION
48 10381780072249 NL83026S04 NL83026S04 MINI INTEGRA FLAT BOTTOMThe silicone elastomer Integra CSF Reservoir, in connect MINI INTEGRA FLAT BOTTOMThe silicone elastomer Integra CSF Reservoir, in connection with a ventricular catheter, is designed to provide access to the brain and/or cerebrospinal fluid (CSF). Access is obtained by penetrating the reservoir dome with a 25-gauge or smaller needle. In this manner, CSF may be withdrawn or other fluid injected into the reservoir. The mini, dual side inlet reservoir’s inlet tubing enters from the sides of the reservoir rather than from the base. This flat bottom dual side inlet design eliminates the need for a formal burr hole, provides greater latitude in positioning and allows the ventricular catheter to be revised without disturbing the reservoir. Integra™ CSF Reservoir INTEGRA LIFESCIENCES CORPORATION
49 10381780072232 NL83026S03 NL83026S03 MINI INTEGRA CSF RES. CONV MODThe silicone elastomer Integra CSF Reservoir, in c MINI INTEGRA CSF RES. CONV MODThe silicone elastomer Integra CSF Reservoir, in connection with a ventricular catheter, is designed to provide access to the brain and/or cerebrospinal fluid (CSF). Access is obtained by penetrating the reservoir dome with a 25-gauge or smaller needle. In this manner, CSF may be withdrawn or other fluid injected into the reservoir. The mini convertible model incorporates an outlet tube in addition to an inlet tube. The outlet tube may be connected to a distal catheter, allowing the reservoir to be used in a shunting system. Since the distal tip of the outlet tube is plugged, conversion to a shunting system requires cutting off the outlet tube proximal to the plugged end for connection to a distal shunt catheter. This model is a flat bottom design. This mini model is not provided with a ventricular catheter and stylet. Integra™ CSF Reservoir INTEGRA LIFESCIENCES CORPORATION
50 10381780072225 NL83026S02 NL83026S02 MINI INTEGRA CSF RES. SIDEThe silicone elastomer Integra CSF Reservoir, in conne MINI INTEGRA CSF RES. SIDEThe silicone elastomer Integra CSF Reservoir, in connection with a ventricular catheter, is designed to provide access to the brain and/or cerebrospinal fluid (CSF). Access is obtained by penetrating the reservoir dome with a 25-gauge or smaller needle. In this manner, CSF may be withdrawn or other fluid injected into the reservoir. The mini, side inlet reservoir’s inlet tubing enters from the sides of the reservoir rather than from the base. This flat bottom side inlet design eliminates the need for a formal burr hole, provides greater latitude in positioning and allows the ventricular catheter to be revised without disturbing the reservoir. Integra™ CSF Reservoir INTEGRA LIFESCIENCES CORPORATION