FLEBOSET DOUBLE is a disposable transfer set through which substances form 2 dif
FLEBOSET DOUBLE is a disposable transfer set through which substances form 2 different vials containing the same solution may be continuously delivered for: a) IV administration when used in conjunction with a gravity or pump infusion set, with luer-lock connection to the drip chamber, to cannel the solution from the source vials to the infusion set, and b) Pharmacy compounding when used in conjuntion with the Grifill pharmacy compounding device and associated transfers sets. Equipped with a spike on each line and a 0.2um hydrophobic air-filter, it minimizes teh formation of aerosols when preparing/dispensing the source substances.
Fluid transfer set consisting of PVC tubing linking 6 mini-spikes to be used in
Fluid transfer set consisting of PVC tubing linking 6 mini-spikes to be used in conjunction with 2 ways transfer set through which the same substance from up to 6 rubber-stoppered glass vials may be delivered into a final IV container. It is equipped with a 0.2 micron hydrophobic air-filter that minimizes the formation of aerosols when preparing and dispensing the source substances. The spike on each line facilitates easy puncture of thick rubber stoppers of small diameter. The device provides fast fluid addition and extraction due to the large surface area of the air-filter that quickly equalizes pressures.
QUICKPIN is a luer-lock spike used in manual or automated pharmacy compounding f
QUICKPIN is a luer-lock spike used in manual or automated pharmacy compounding for addition and/or extraction of IV substances from rubber stoppered containers including multi-dose vials.
SETS GRI-FILL 3.0 are fluid transfer sets for use with the GRI-FILL 3.0 pharmacy
SETS GRI-FILL 3.0 are fluid transfer sets for use with the GRI-FILL 3.0 pharmacy compounding device in order to compound or mix different multi-ingredient solutions and to channel them into a final suitable IV container. The set is a disposable component of the compounding device. The 1 WAY / 2 WAY models are made up of a syringe, a distributor, tubing to channel the fluid and a waste/residue bag. Sets are available for 1 or 2 source substances. Also a Luer female - female adapter is available as an accessory to the I or 2 way transfer sets. The MULTIPLE model is also used as an accessory with the 1IWAY I 2WAY sets for channeling the same solution from up to six (6) source containers delivering them into a final IV container. It is made up of connectors and tubing to enable interconnection of the different source containers.
SETS GRI-FILL 3.0 are fluid transfer sets for use with the GRI-FILL 3.0 pharmacy
SETS GRI-FILL 3.0 are fluid transfer sets for use with the GRI-FILL 3.0 pharmacy compounding device in order to compound or mix different multi-ingredient solutions and to channel them into a final suitable IV container. The set is a disposable component of the compounding device. The 1 WAY / 2 WAY models are made up of a syringe, a distributor, tubing to channel the fluid and a waste/residue bag. Sets are available for 1 or 2 source substances. Also a Luer female - female adapter is available as an accessory to the 1 or 2 way transfer sets. The MULTIPLE model is also used as an accessory with the 1IWAY I 2WAY sets for channeling the same solution from up to six (6) source containers delivering them into a final IV container. It is made up of connectors and tubing to enable interconnection of the different source containers.
SETS GRI-FILL 3.0 are fluid transfer sets for use with the GRI-FILL 3.0 pharmacy
SETS GRI-FILL 3.0 are fluid transfer sets for use with the GRI-FILL 3.0 pharmacy compounding device in order to compound or mix different multi-ingredient solutions and to channel them into a final suitable IV container. The set is a disposable component of the compounding device. The 1 WAY / 2 WAY models are made up of a syringe, a distributor, tubing to channel the fluid and a waste/residue bag. Sets are available for 1 or 2 source substances. Also a Luer female - female adapter is available as an accessory to the 1 or 2 way transfer sets. The MULTIPLE model is also used as an accessory with the 1IWAY I 2WAY sets for channeling the same solution from up to six (6) source containers delivering them into a final IV container. It is made up of connectors and tubing to enable interconnection of the different source containers.
FLEBOSET MULTIPLE is a fluid transfer tubing set used to enable continuous (unin
FLEBOSET MULTIPLE is a fluid transfer tubing set used to enable continuous (uninterrupted) delivery of drug solutions from 6 glass source containers. It is used in pharmacy compounding or for IV fluid transfer to minimize manipulation when working with small volumen source containers. The device is made up of 6 spikes connected in series with flexible tubing segments, each segment with an idividual clamp. The set terminal, for connection to the pharmacy compounding device sets or administration sets (gravity or pump) consists of a spikeable twist-off valve connector.
Gri-fill 2 Ways Set is a fluid transfer set for use with the Gri-fill pharmacy c
Gri-fill 2 Ways Set is a fluid transfer set for use with the Gri-fill pharmacy compounding device in order to compound or mix different multi-ingredient solutions and to channel them into a final suitable IV container. The set is a disposable component of the compounding device. Gri-fill 2 Ways Set is made up of a syringe, a distributor, tubing to channel the fluid and a waste/residue bag. Set is available for 1 or 2 source substances. Also a Luer female - female adapter is available as an accessory to the Gri-fill 2 Ways Set.
Gri-fill Peristaltic Set is an IV fluid transfer set to be used in conjunction w
Gri-fill Peristaltic Set is an IV fluid transfer set to be used in conjunction with the Gri-Fill Pharmacy Compounder and ancillary Gri-Fill sets in hospital pharmacy to provide a fluid pathway through which one source substance is channeled repeatedly to an IV container. It consists of a silicone tube linking a male luer-lock connector and a spike (with a 0.2 µm hydrophobic air filter), and a female luer-lock connection.