The Piccolo® AmLyte 13 , used with the Piccolo Xpress® chemistry analyzer, is in
The Piccolo® AmLyte 13 , used with the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), albumin, amylase, aspartate aminotransferase (AST), calcium, c-reactive protein (CRP), creatine kinase, creatinine, glucose, potassium, sodium, total bilirubin and blood urea nitrogen (BUN) in lithium heparinized whole blood, lithium heparinized plasma, or serum in a clinical laboratory setting or point-of-care location. The Abaxis CRP method is not intended for high sensitivity CRP measurement.
The Piccolo® BioChemistry Panel Plus, used with the Piccolo Xpress® chemistry an
The Piccolo® BioChemistry Panel Plus, used with the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), albumin, alkaline phosphatase (ALP), amylase, aspartate aminotransferase (AST), c-reactive protein (CRP), calcium, creatinine, gamma glutamyltransferase (GGT), glucose, total protein, blood urea nitrogen (BUN), and uric acid in lithium heparinized whole blood, lithium heparinized plasma, or serum in a clinical laboratory setting or point-of-care location. The Abaxis CRP method is not intended for high sensitivity CRP measurement.
The Piccolo® Lipid Panel Plus, used with the Piccolo® blood chemistry analyzer o
The Piccolo® Lipid Panel Plus, used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, is intended for the in vitro quantitative determination of total cholesterol (CHOL), high-density lipoprotein cholesterol (HDL), triglycerides (TRIG), alanine aminotransferase (ALT), aspartate aminotransferase (AST), and glucose (GLU) in capillary (fingerstick) lithium heparinized whole blood, venous lithium heparinized whole blood, lithium heparinized plasma, or serum in a clinical laboratory setting or point-of-care location. From the CHOL, HDL and TRIG determinations, low-density lipoprotein cholesterol (LDL), very low-density lipoprotein cholesterol (VLDL), non-HDL cholesterol, and a total cholesterol/high-density lipoprotein cholesterol ratio (TC/H) are calculated by the analyzer.Lipid measurements are used in the diagnosis and treatment of lipid and lipoprotein disorders, atherosclerosis, various liver and renal diseases, diabetes mellitus, and other diseases involving lipid metabolism or various endocrine disorders.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood (venous or capillary) may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
The Piccolo® General Chemistry 13 used with the Piccolo blood chemistry analyzer
The Piccolo® General Chemistry 13 used with the Piccolo blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), albumin, alkaline phosphatase (ALP), amylase, aspartate aminotransferase (AST), calcium, creatinine, gamma glutamyltransferase (GGT), glucose, total bilirubin, total protein, blood urea nitrogen (BUN), and uric acid in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
The Piccolo® Comprehensive Metabolic Panel, used with the Piccolo® blood chemist
The Piccolo® Comprehensive Metabolic Panel, used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), albumin, alkaline phosphatase (ALP), aspartate aminotransferase (AST), calcium, chloride, creatinine, glucose, potassium, sodium, total bilirubin, total carbon dioxide, total protein, and blood urea nitrogen (BUN) in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
The Piccolo® Hepatic Function Panel, used with the Piccolo Xpress® chemistry ana
The Piccolo® Hepatic Function Panel, used with the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitroquantitative determinations of alanine aminotransferase, albumin, alkaline phosphatase, aspartate aminotransferase, directbilirubin, total bilirubin, and total protein in heparinized whole blood, heparinized plasma, or serum in a clinical laboratorysetting or point-of-care location.
The Piccolo® General Chemistry 6 , used with the Piccolo® blood chemistry analyz
The Piccolo® General Chemistry 6 , used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), aspartate aminotransferase (AST), creatinine, gamma glutamyltransferase (GGT), glucose, and blood urea nitrogen (BUN) in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
The Piccolo® Liver Panel Plus, used with the Piccolo® blood chemistry analyzer o
The Piccolo® Liver Panel Plus, used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, utilizes dry and liquid reagents to provide in vitro quantitative determinations of alanine aminotransferase, albumin, alkaline phosphatase, amylase, aspartate aminotransferase, gamma glutamyltransferase, total bilirubin, and total protein in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
For the quantitative determination of Alanine Aminotransferase (ALT) in serum us
For the quantitative determination of Alanine Aminotransferase (ALT) in serum using the Mindray BS-200 analyzer.2 x 40 ml, 2 x 10 ml
For the quantitative in vitro determination of Alanine Aminotransferase (ALT) in
For the quantitative in vitro determination of Alanine Aminotransferase (ALT) in serum and plasma.6 x 51 ml, 6 x 14 ml
For the quantitative determination of alkaline phosphatase in human serum using
For the quantitative determination of alkaline phosphatase in human serum using the Mindray BS-480 analyzer. In vitro diagnostic medical device.5 x 60 ml, 5 x 15 ml.
For the quantitative determination of Alanine Aminotransferase in serum. ALT is
For the quantitative determination of Alanine Aminotransferase in serum. ALT is widely distributed in tissues with the highest concentrations found in the liver and kidneys. Even so, ALT is considered more liver-specific than AST. Elevated levels of ALT are often only observed in liver diseases such as cirrhosis, hepatitis, or metastatic carcinoma. However, there can be elevated levels of ALT with infectious mononucleosis, muscular dystrophy, and dermatomyositis.
Pointe ALT Reagent packaged for use on the Mindray BA800. 5 x 67ml R1, 5 x 17ml
Pointe ALT Reagent packaged for use on the Mindray BA800. 5 x 67ml R1, 5 x 17ml R2. For the quantitative determination of Alanine Aminotransferase in serum.
Pointe ALT packaged for the BS480 Analyzer. 5x60mL, 5x15mL Kit. For the quantit
Pointe ALT packaged for the BS480 Analyzer. 5x60mL, 5x15mL Kit. For the quantitative determination of Alanine Aminotransferase in serum on the BS480 Analyzer.
Pointe Scientific, Inc. ALT Reagent is for the quantitative determination of Ala
Pointe Scientific, Inc. ALT Reagent is for the quantitative determination of Alanine Aminotransferase in serum. Packaged with barcodes for use on AU400, AU480 and AU640.6 x 67ml, 5 x 17ml.
ALT Reagent, for the quantitative determination of Alanine Aminotransferase in s
ALT Reagent, for the quantitative determination of Alanine Aminotransferase in serum. Size: 1 x 2L, 1 x 500mL
ALT reagent for the quantitative determination of alanine aminotransferase in se
ALT reagent for the quantitative determination of alanine aminotransferase in serum on Hitachi analyzers. For in vitro diagnostic use only.6 x 67ml, 6 x 17ml
ALT Reagent Set for the quantitative determination of alanine aminotransferase i
ALT Reagent Set for the quantitative determination of alanine aminotransferase in serum on Hitachi analyzers. For in vitro diagnostic use only. Packaged at 5 x 100ml, 2 x 55ml
For the Kinetic Quantitative Determination of ALT/ GPT in Serum for Manual and/o
For the Kinetic Quantitative Determination of ALT/ GPT in Serum for Manual and/or Automated Procedures.
For the Kinetic Quantitative Determination of ALT/ GPT in Serum for Manual and/o
For the Kinetic Quantitative Determination of ALT/ GPT in Serum for Manual and/or Automated Procedures.