DUAL SPRAY MDI ADAPTER WITH COUNTER INCREMENTING ACTUATOR AND 15MM O.D. X 15MM I
DUAL SPRAY MDI ADAPTER WITH COUNTER INCREMENTING ACTUATOR AND 15MM O.D. X 15MM I.D. CONNECTIONS
DUAL SPRAY MDI ADAPTER WITH COUNTER INCREMENTING ACTUATOR AND 22MM O.D. X 22MM I
DUAL SPRAY MDI ADAPTER WITH COUNTER INCREMENTING ACTUATOR AND 22MM O.D. X 22MM I.D. CONNECTIONS
DUAL SPRAY MDI ADAPTER WITH COUNTER INCREMENTING ACTUATOR AND 22MM O.D. X 22MM O
DUAL SPRAY MDI ADAPTER WITH COUNTER INCREMENTING ACTUATOR AND 22MM O.D. X 22MM O.D. CONNECTIONS
DUAL VALVED, COLLAPSIBLE MDI HOLDING CHAMBER: CATALOG NUMBER 1303 IS 1 INDIVIDUA
DUAL VALVED, COLLAPSIBLE MDI HOLDING CHAMBER: CATALOG NUMBER 1303 IS 1 INDIVIDUAL LITEAIRE UNIT. CATALOG NUMBER 1304 IS 1 DISPENSER BOX CONTAINING 25 INDIVIDUAL LITEAIRE UNITS IN A SHIPPING CONTAINER. CATALOG NUMBER 1306 IS 4 DISPENSER BOXES, EACH CONTAINING 25 LITEAIRE UNITS (100 LITEAIRE UNITS IN TOTAL) IN A SHIPPING CONTAINER.
CAF,NVP
Nebulizer (Direct Patient Interface),Holding Chambers, Direct Patient Interface
The O-Two single-use electronic ventilator ventilation circuit consists of a sin
The O-Two single-use electronic ventilator ventilation circuit consists of a single ventilation corrugated hose and equipped with a flow sensor adapter designed to stream the flow without turbulence and create a differential pressure in two points which are connected to differential pressure sensor used to calculate flow. The unique one-way check valve will only allow flow from ventilator to patient and prevent the exhaled flow flowing back to the ventilator. All exhaled flow will be forced out to the atmosphere through the exhausted port of the breathing valve. The 01CV8030 is specifically designed for use with o_two e700, e600 and e500 electronic transport ventilators.
The O-Two single-use ventilation circuit is designed to be used with ventilators
The O-Two single-use ventilation circuit is designed to be used with ventilators, demand valve or gas mixers to deliver oxygen or nitrous oxide and oxygen mixture gas to patients. It consists of one corrugated breathing hose, an inspiratory one-way valve, and a PEEP port. The 01CV8019 with anti-entrainment flapper and facemask/mouth piece is specifically designed for use with O-Two Equinox Relieve and Equinox Advantage nitrous oxide and oxygen gas mixing and delivery units.
The O-Two single-use ventilation circuit is designed to be used with ventilators
The O-Two single-use ventilation circuit is designed to be used with ventilators, demand valve or gas mixers to deliver oxygen or nitrous oxide and oxygen mixture gas to patients. It consists of one corrugated breathing hose, an inspiratory one-way valve, and a PEEP port. The 01CV8016 is specifically designed for use with CAREvent MRI ventilators and is long enough to allow free passage of the patient in and out of the MRI unit without the risk of pulling on the tubing.
The O-Two single-use ventilation circuit is designed to be used with ventilators
The O-Two single-use ventilation circuit is designed to be used with ventilators, demand valve or gas mixers to deliver oxygen or nitrous oxide and oxygen mixture gas to patients. It consists of one corrugated breathing hose, an inspiratory one-way valve, and a PEEP port. The 01CV8015 with anti-entrainment flapper is specifically designed for use on O-Two automatic resuscitators and transport ventilators and other ventilators that respond to the spontaneous breathing.
The O-Two single-use ventilation circuit is designed to be used with ventilators
The O-Two single-use ventilation circuit is designed to be used with ventilators, demand valve or gas mixers to deliver oxygen or nitrous oxide and oxygen mixture gas to patients. It consists of one corrugated breathing hose, an inspiratory one-way valve. The 01CV8010 is specifically designed for use on Bag-Valve-Mask resuscitators and ventilators without demand breathing or patient triggered ventilation modes.
Following Device Identifier numbers are included in this KIT:17325710002503,1732
Following Device Identifier numbers are included in this KIT:17325710002503,17325710004576,17325710002367
Following Device Identifier numbers are included in this KIT:17325710002244,1732
Following Device Identifier numbers are included in this KIT:17325710002244,17325710004576,17325710002466
Following Device Identifier numbers are included in this KIT:17325710002169,1732
Following Device Identifier numbers are included in this KIT:17325710002169,17325710004576,17325710002091,17325710002398
Following Device Identifier numbers are included in this KIT:17325710002619,1732
Following Device Identifier numbers are included in this KIT:17325710002619,17325710004576,17325710002176,17325710002374
Parallel 1.8m (71") Circuit + Mon Line + Luer Elbow + 3L Res Bag + 1m Limb + Bag
Parallel 1.8m (71") Circuit + Mon Line + Luer Elbow + 3L Res Bag + 1m Limb + Bag Arm(038-01-110/1GE)
Parallel 1.8m (71") Circuit + Mon Line + Luer Elbow + 3L Res Bag + 1m Limb + Bag
Corrugated Limb 0.9m(35") + Bag Arm Connector +1 x 22F Connector + 2L Reservoir
Corrugated Limb 0.9m(35") + Bag Arm Connector +1 x 22F Connector + 2L Reservoir Bag (038-01-239GE)
Corrugated Limb 0.9m(35") + Bag Arm Connector +1 x 22F Connector + 2L Reservoir