Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter - The IVL Catheter is a proprietary lithotripsy - Shockwave Medical, Inc.

Duns Number:055514478

Device Description: The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arte The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable.

Want to know more about this Product? Request more information now!


More Product Details

Catalog Number

L6IVL080030

Brand Name

Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter

Version/Model Number

8.0x30mm

Device Commercial Distribution Status

In Commercial Distribution

Commercial Distribution End Date

-

Issuing Agency

In GS1

Product Characteristics

MRI safety Status

Labeling does not contain MRI Safety Information

Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437)

-

Device labeled as "Not made with natural rubber latex"

-

For Single-Use

Yes

Prescription Use (Rx)

Yes

Over the Counter (OTC)

-

Kit

-

Combination Product

-

Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P)

-

FDA Premarket Submission

K221852

Product Code Details

Product Code

JAA

Product Code Name

System, X-Ray, Fluoroscopic, Image-Intensified

Device Record Status

Public Device Record Key

49811c55-7081-4d34-b2f7-c99491adccc5

Public Version Date

November 01, 2022

Public Version Number

1

DI Record Publish Date

October 24, 2022

Additional Identifiers

Package DI Number

None

Quantity per Package

-

Contains DI Package

-

Package Discontinue Date

-

Package Status

-

Package Type

-

"SHOCKWAVE MEDICAL, INC." Characteristics
Device Class Device Class Description No of Devices
2 A medical device with a moderate to high risk that requires special controls. 56
3 A medical device with high risk that requires premarket approval 4