Other products from "AMERICAN CONTRACT SYSTEMS, INC."
No Primary DI Version or Model Catalog Number Device Description Product Code Product Code Name Device Class Brand Name
1 00191072009531 NMMJ39S MAJOR PACK LRO General surgery tray 2 ACS
2 00191072009425 GIDI10E DIALYSIS ON/OFF PACK LRO General surgery tray 2 ACS
3 00191072009395 NMER48M EAR PACK LRO General surgery tray 2 ACS
4 00191072000019 AHCC45A CLEAN CLOSURE PACK - 289126 LRO General surgery tray 2 ACS
5 00191072154132 CACS20G C-SECTION PACK OHM Cesarean section tray 2 ACS
6 00191072154125 OSIN77D IR NEURO PACK OJG Neurological tray 1 ACS
7 00191072154118 HIPP64K ILLINI PACEMAKER PACK OEZ Cardiovascular procedure kit 2 ACS
8 00191072154101 PDLS20F LAPAROSCOPY LRO General surgery tray 2 ACS
9 00191072154095 SVTU25E TUR PACK 156957 NWU Endoscope introducer kit 2 ACS
10 00191072154088 MHHY51I HYBRID CV PACK OEQ Angiography/angioplasty kit 2 ACS
11 00191072178855 LAAH06F ANTERIOR HIP OJH Orthopedic tray 1 ACS
12 00191072178305 FHTA31P T & A PACK OGR Ear, nose, and throat surgical tray 1 ACS
13 00191072178299 FHSH28AF SHOULDER & HIP PACK OJH Orthopedic tray 1 ACS
14 00191072177810 BHLV40L LAVH OJF Hysterectomy kit 2 ACS
15 00191072177803 BHLI99I LITHOTOMY OHD Gynecological laparoscopic kit 2 ACS
16 00191072177797 BHLH43L PELVISCOPY OHD Gynecological laparoscopic kit 2 ACS
17 00191072177780 BHLE58I LOWER EXTREMITY OJH Orthopedic tray 1 ACS
18 00191072177766 BHLA24N LAMI OJG Neurological tray 1 ACS
19 00191072177469 BLSE37L SURGICAL EYE PACK OJK Eye tray 2 ACS
20 00191072177759 BHDS41D MIDLINE DRESSING CHANGE LRO General surgery tray 2 ACS
21 00191072177438 LLCA38I CVL CATH LAB PACK OES Cardiac catheterization kit 2 ACS
22 00191072177742 BHDM27F L&D MINOR PACK MLS Labor and Delivery Kit 2 ACS
23 00191072177735 BHCY71J MAJOR CYSTO NWU Endoscope introducer kit 2 ACS
24 00191072177728 BHCS31L C-SECTION OHM Cesarean section tray 2 ACS
25 00191072177711 BHCR22Q CRANIOTOMY OJG Neurological tray 1 ACS
26 00191072162960 HSHI92P HIP ARTHROSCOPY PACK OJH Orthopedic tray 1 ACS
27 00191072162953 LLPP48I PEDS PACK LRO General surgery tray 2 ACS
28 00191072162946 HSKA48L KNEE ARTHRO PACK OJH Orthopedic tray 1 ACS
29 00191072162939 LLPA19I CVL PACEMAKER PACK OEZ Cardiovascular procedure kit 2 ACS
30 00191072162922 LLMS45H MASTECTOMY PACK FTN Plastic surgery and accessories kit 1 ACS
31 00191072162915 HSPO50N PODIATRY PACK OJH Orthopedic tray 1 ACS
32 00191072162908 LLML48G MAJOR LITHOTOMY PACK OHD Gynecological laparoscopic kit 2 ACS
33 00191072162892 LLLS28H LAPAROSCOPY PACK FDE laparoscopy kit 2 ACS
34 00191072162885 LLLP55F UNIVERSAL LAPAROTOMY PACK LRO General surgery tray 2 ACS
35 00191072162878 LLLG34H LEG PACK OJH Orthopedic tray 1 ACS
36 00191072162861 HSBR41M BREAST PACK LRO General surgery tray 2 ACS
37 00191072162854 LLKD89F KIDNEY TRANSPLANT PACK LRO General surgery tray 2 ACS
38 00191072162847 LLHN44H HEAD & NECK AUXILIARY PACK LRO General surgery tray 2 ACS
39 00191072162823 HSWA82N DR. WARME ACL PACK OJH Orthopedic tray 1 ACS
40 00191072162816 LLHD88H UNIVERSAL HAND PACK OJH Orthopedic tray 1 ACS
41 00191072162809 LLGP47G GYN LAPAROSCOPY PACK OHD Gynecological laparoscopic kit 2 ACS
42 00191072162793 LLEC88D ADULT ECMO HEART PACK OEQ Angiography/angioplasty kit 2 ACS
43 00191072162786 HSEE43N EENT PACK OGR Ear, nose, and throat surgical tray 1 ACS
44 00191072162779 LLEC31L EAR PACK OGR Ear, nose, and throat surgical tray 1 ACS
45 00191072162762 LLCT45J PEDS CRANIOTOMY PACK OJG Neurological tray 1 ACS
46 00191072162755 LLCR99H ADULT CRANIOTOMY PACK OJG Neurological tray 1 ACS
47 00191072162748 HSPH40N DR. BEAN/DR. POAG HAND PACK OJH Orthopedic tray 1 ACS
48 00191072162731 LLBB26G BASIC BACK PACK LRO General surgery tray 2 ACS
49 00191072162724 LLUR11L URO ROBOTIC PPS NWU Endoscope introducer kit 2 ACS
50 00191072162717 HSAC62N ACL PACK OJH Orthopedic tray 1 ACS
Other products with the same Product Code "OEZ"
No Primary DI Version or Model Catalog Number Device Description Brand Name Organization Name
1 00827002236523 G23652 MSB-TRAY-DRY Maximal Sterile Barrier Bedside Tray Cook COOK INCORPORATED
2 00827002208995 G20899 MSB-TRAY Maximal Sterile Barrier Bedside Tray Cook COOK INCORPORATED
3 00811870035555 CLT-19914 Custom Healthcare Systems of VA, LLC CUSTOM HEALTHCARE SYSTEMS, INC.
4 00811870035371 KM-CBMT Custom Healthcare Systems of VA, LLC CUSTOM HEALTHCARE SYSTEMS, INC.
5 00811870034046 M100-19608 CUSTOM HEALTHCARE SYSTEMS, INC CUSTOM HEALTHCARE SYSTEMS, INC.
6 00811870033216 UNC-17914 Custom Healthcare Systems Inc. CUSTOM HEALTHCARE SYSTEMS, INC.
7 00811870032479 M100 Custom Healthcare Systems Inc. CUSTOM HEALTHCARE SYSTEMS, INC.
8 00811870032172 CDWS-19145 Custom Healthcare Systems Inc. CUSTOM HEALTHCARE SYSTEMS, INC.
9 00195451000416 12.0x30mm L6IVL120030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
10 00195451000409 10.0x30mm L6IVL100030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
11 00195451000393 9.0x30mm L6IVL090030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
12 00195451000386 8.0x30mm L6IVL080030 The IVL Catheter is a proprietary lithotripsy device delivered through the perip The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Energizing the lithotripsy device will generate pulsatile mechanical energy within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. The IVL Catheter is comprised of an integrated balloon with an array of lithotripsy emitters for the localized delivery of pulsatile mechanical energy. The system consists of an IVL Catheter, an IVL Connector Cable and an IVL Generator. The IVL Catheter is available in four (4) sizes: 8.0 x 30mm, 9.0 x 30mm, 10.0 x 30mm, and 12.0 x 30mm. The L6 Peripheral IVL Catheter is compatible with a 7 or 8F sheath and has a working length of 110cm.The Shockwave L6 Peripheral IVL Catheter shaft contains an inflation lumen, a guidewire lumen, and the lithotripsy emitters. The inflation lumen is used for inflation and deflation of the balloon with 50/50 saline/contrast medium. The guidewire lumen enables the use of a 0.018” guidewire to facilitate advancement of the catheter to and through the target stenosis. The system is designed as ‘Over-the-wire’ (OTW) with 110cm shaft working length, so an exchange length (300cm) guidewire is indicated. The emitters are positioned along the length of the balloon working length for delivery of pulsatile mechanical energy. The balloon is located near the distal tip of the catheter. Two radiopaque marker bands within the balloon denote the length of the balloon to aid in positioning of the balloon during treatment. The balloon is designed to provide an expandable segment of known length and diameter at a specific pressure. The proximal hub has three ports: one for inflation/deflation of the balloon, one for guidewire lumen, and one for connection to the IVL Connector Cable. Shockwave Medical L6 Intravascular Lithotripsy (IVL) Catheter SHOCKWAVE MEDICAL, INC.
13 00195451000348 4.0x40mm S4IVLK4040 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
14 00195451000331 3.5x40mm S4IVLK3540 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
15 00195451000324 3.0x40mm S4IVLK3040 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
16 00195451000317 2.5x40mm S4IVLK2540 The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array o The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave S4 SHOCKWAVE MEDICAL, INC.
17 00195451000287 8.0x60mm M5PIVL8060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
18 00195451000270 7.0x60mm M5PIVL7060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
19 00195451000263 6.5x60mm M5PIVL6560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
20 00195451000256 6.0x60mm M5PIVL6060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
21 00195451000249 5.5x60mm M5PIVL5560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
22 00195451000232 5.0x60mm M5PIVL5060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
23 00195451000225 4.5x60mm M5PIVL4560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
24 00195451000218 4.0x60mm M5PIVL4060 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
25 00195451000201 3.5x60mm M5PIVL3560 The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator). Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave M5+ SHOCKWAVE MEDICAL, INC.
26 00191072178947 LAPM00J PACEMAKER ACS AMERICAN CONTRACT SYSTEMS, INC.
27 00191072178787 BLPA73P PACEMAKER PACK ACS AMERICAN CONTRACT SYSTEMS, INC.
28 00191072178633 BLCV74L CV OR BASIN DRAPE PACK B ACS AMERICAN CONTRACT SYSTEMS, INC.
29 00191072178541 SAVT92F VEIN TRAY ACS AMERICAN CONTRACT SYSTEMS, INC.
30 00191072178510 SAPA90Z PACEMAKER ACS AMERICAN CONTRACT SYSTEMS, INC.
31 00191072178367 BLCV78M CV OR PACK A ACS AMERICAN CONTRACT SYSTEMS, INC.
32 00191072178251 FHPM10R PACEMAKER PACK ACS AMERICAN CONTRACT SYSTEMS, INC.
33 00191072178244 FHPE19J PERIPHERAL PACK ACS AMERICAN CONTRACT SYSTEMS, INC.
34 00191072178176 FHHR16V CUSTOM HEART PACK II ACS AMERICAN CONTRACT SYSTEMS, INC.
35 00191072178053 SACV80L OPEN HEART (SACV01/SACV02) ACS AMERICAN CONTRACT SYSTEMS, INC.
36 00191072178046 SACV02L HEART PART 2 ACS AMERICAN CONTRACT SYSTEMS, INC.
37 00191072178039 SACV01L HEART PART 1 ACS AMERICAN CONTRACT SYSTEMS, INC.
38 00191072178022 FHHP15Y CUSTOM HEART PACK I ACS AMERICAN CONTRACT SYSTEMS, INC.
39 00191072178015 BHVP49K VASCULAR ADD ON PACK ACS AMERICAN CONTRACT SYSTEMS, INC.
40 00191072177988 BHTY48P THORACOTOMY ACS AMERICAN CONTRACT SYSTEMS, INC.
41 00191072177896 BHPM65O PACEMAKER ACS AMERICAN CONTRACT SYSTEMS, INC.
42 00191072177872 BHOH95O OPEN HEART MAYFIELD B ACS AMERICAN CONTRACT SYSTEMS, INC.
43 00191072177865 BHOH94L OPEN HEART BACK TABLE A ACS AMERICAN CONTRACT SYSTEMS, INC.
44 00191072177414 CEVS11P VASCULAR PACK ACS AMERICAN CONTRACT SYSTEMS, INC.
45 00191072176196 FRVH22I VEIN HARVEST ACS AMERICAN CONTRACT SYSTEMS, INC.
46 00191072176189 FRVA25K VASCULAR PACK ACS AMERICAN CONTRACT SYSTEMS, INC.
47 00191072176097 FRCA60AF CABG PACK ACS AMERICAN CONTRACT SYSTEMS, INC.
48 00191072175892 RWAA01H ANEURYSM--LF ACS AMERICAN CONTRACT SYSTEMS, INC.
49 00191072175748 CXPA35R PACER ACS AMERICAN CONTRACT SYSTEMS, INC.
50 00191072175687 CXIM40F IMPLANT PACK ACS AMERICAN CONTRACT SYSTEMS, INC.