Address:Keilasatama 5,Espoo Uusimaa,FI
Device Description : The Elekta Neuromag® TRIUX non-invasively measures the magnetoencephalographic ( The Elekta Neuromag® TRIUX non-invasively measures the magnetoencephalographic (MEG) signals (and, optionally, electroencephalographic (EEG) signals) produced by electrically active tissue of the brain. These signals are recorded by a computerized data acquisition system, displayed, and may then be interpreted by trained physicians to help localize these active areas. The locations may then be correlated with anatomical information of the brain. MEG is routinely used to identify the locations of visual, auditory, somatosensory, and motor cortex in the brain when used in conjunction with evoked response averaging devices. MEG is also used to non-invasively locate regions of epileptic activity within the brain. The localization information provided by MEG may be used, in conjunction with other diagnostic data, in neurosurgical planning.
Device Class : 2
Duns Number: 538025107
Premarket Exempt : No
Prescription Use : No
Device Description : The Elekta Neuromag® TRIUX non-invasively measures the magnetoencephalographic ( The Elekta Neuromag® TRIUX non-invasively measures the magnetoencephalographic (MEG) signals (and, optionally, electroencephalographic (EEG) signals) produced by electrically active tissue of the brain. These signals are recorded by a computerized data acquisition system, displayed, and may then be interpreted by trained physicians to help localize these active areas. The locations may then be correlated with anatomical information of the brain. MEG is routinely used to identify the locations of visual, auditory, somatosensory, and motor cortex in the brain when used in conjunction with evoked response averaging devices. MEG is also used to non-invasively locate regions of epileptic activity within the brain. The localization information provided by MEG may be used, in conjunction with other diagnostic data, in neurosurgical planning.
Device Class : 2
Duns Number: 538025107
Premarket Exempt : No
Prescription Use : No
Device Description : A comprehensive analysis suite for magnetoencephalographic and electroencephalog A comprehensive analysis suite for magnetoencephalographic and electroencephalographic data acquired with Elekta Neuromag®, Elekta Neuromag® TRIUX and TRIUX™ neo.
Device Class : 2
Duns Number: 538025107
Premarket Exempt : No
Prescription Use : No
Device Description : MaxFilter™ is used with Elekta Neuromag®, Elekta Neuromag® TRIUX and TRIUX™ neo MaxFilter™ is used with Elekta Neuromag®, Elekta Neuromag® TRIUX and TRIUX™ neo in suppressing magnetic interference and in reducing measurement artifacts.
Device Class : 2
Duns Number: 538025107
Premarket Exempt : No
Prescription Use : No
Device Description : Adjustable patient chair with accessories for comfortable seated measurement position.
Device Class : 2
Duns Number: 538025107
Premarket Exempt : No
Prescription Use : No
Device Description : Patient couch for the supine measurement position.
Device Class : 2
Duns Number: 538025107
Premarket Exempt : No
Prescription Use : No
Device Description : A booster seat and neck collar for pediatric patients.
Device Class : 2
Duns Number: 538025107
Premarket Exempt : No
Prescription Use : No
Device Description : A binaural auditory stimulator for eliciting auditory evoked fields.
Device Class : 2
Duns Number: 538025107
Premarket Exempt : No
Prescription Use : No
Device Description : A bilateral finger response system for detecting patient responses.
Device Class : 2
Duns Number: 538025107
Premarket Exempt : No
Prescription Use : No
Device Description : A head position coil set for tracking the position of the patient's head.
Device Class : 2
Duns Number: 538025107
Premarket Exempt : No
Prescription Use : No