Chongqing Kanghuaruiming S&T Co., Ltd..

Address:NO.5, Road 1, Tongjiaxi Industrial Park,,Chongqing,CN

Want to know more about this Organization? Request more information now!


Filters
Device Class
Product Code
Premarket Exempt
Clear
- Catalog Number :

Device Class : 2

Duns Number: 543066376

Premarket Exempt : No

Product Code : HJO

Prescription Use : Yes

Device Count : 1

- Catalog Number :

Device Description : The KH Ophthalmic Slit-lamp Microscope is an AC-powered device that is a microsc The KH Ophthalmic Slit-lamp Microscope is an AC-powered device that is a microscope intended for use in eye examination that projects into a patient's eye through a control diaphragm a thin, intense beam of light. The KH Ophthalmic Slit-lamp Microscope is composed of the following components: microscope unit, illumination unit, base unit, chinrest, and table and power unit. The slit-lamp biomicroscope is used for the observation of the eye. It has an illumination unit to illuminate the eye, and a binocular stereoscopic microscope to zoom and observe patient's eyes, and also can observe the three-dimensional image.

Device Class : 2

Duns Number: 543066376

Premarket Exempt : No

Product Code : HJO

Prescription Use : Yes

Device Count : 1

- Catalog Number :

Device Description : The KH Ophthalmic Slit-lamp Microscope is an AC-powered device that is a microsc The KH Ophthalmic Slit-lamp Microscope is an AC-powered device that is a microscope intended for use in eye examination that projects into a patient’s eye through a control diaphragm a thin, intense beam of light. The KH Ophthalmic Slit-lamp Microscope is composed of the following components: microscope unit, illumination unit, base unit, chinrest, and table and power unit. The slitlamp biomicroscope is used for the observation of the eye. It has an illumination unit to illuminate the eye, and a binocular stereoscopic microscope to zoom and observe patient’s eyes, and also can observe the three-dimensional image.

Device Class : 2

Duns Number: 543066376

Premarket Exempt : No

Product Code : HJO

Prescription Use : Yes

Device Count : 1

- Catalog Number :

Device Description : This device is used to create digital colour photographic images of the ocular f This device is used to create digital colour photographic images of the ocular fundus through the pupil, to aid in diagnosing and monitoring retinal pathology.

Device Class : 2

Duns Number: 543066376

Premarket Exempt : Yes

Product Code : HKI

Prescription Use : Yes

Device Count : 1

- Catalog Number :

Device Description : This system adopts the most advanced Optical-electro-mechanical Integration tech This system adopts the most advanced Optical-electro-mechanical Integration technology. It integrates digital Fundus-Fluorescein-Angiography camera and digital-fundus-images acquisition and processing system, which can continuously display real-time, high quality color fundus images as well as black-white Fundus-Fluorescein-Angiography video images. The fundus images acquisition and processing system can process (full digital), record (real-time and completely) and save the color fundus images as well as retinal-fluorescein-angiography dynamic & static images into the computer. You can modify pictures, check reports, edit Graph-texts and manage all the dates at any time you want; you can measure and calculate the size of the case focus; you can zoom, move, stick, and put together the pictures; you can adjust the color on the picture, you can also record all the data on the CD, which can assistant scientific research and teaching. This system has combine function of many fundus image acquisition instruments, which can support medical treatments.

Device Class : 2

Duns Number: 543066376

Premarket Exempt : Yes

Product Code : HKI

Prescription Use : Yes

Device Count : 1

- Catalog Number :

Device Description : The projection perimeters is used to check the sensitivity of the human eye to l The projection perimeters is used to check the sensitivity of the human eye to light(visual acuity). Ambient light by refraction system to the retina, the retinal photochemical reactions by bioelectrical, transmitted through the visual pathway visual cortex, the brain through a comprehensive analysis of the formation of vision. Any part of the distribution from the retina to the visual cortex nerve fibers, direction, known as the road lesions occur, it will be reflected in the vision, visual field changes according to the results of other tests and clinical, can analyze the site of the lesion, nature and prognosis.

Device Class : 1

Duns Number: 543066376

Premarket Exempt : Yes

Product Code : HPT

Prescription Use : Yes

Device Count : 1

- Catalog Number :

Device Description : The projection perimeters is used to check the sensitivity of the human eye to l The projection perimeters is used to check the sensitivity of the human eye to light(visual acuity). Ambient light by refraction system to the retina, the retinal photochemical reactions by bioelectrical, transmitted through the visual pathway visual cortex, the brain through a comprehensive analysis of the formation of vision. Any part of the distribution from the retina to the visual cortex nerve fibers, direction, known as the road lesions occur, it will be reflected in the vision, visual field changes according to the results of other tests and clinical, can analyze the site of the lesion, nature and prognosis.

Device Class : 1

Duns Number: 543066376

Premarket Exempt : Yes

Product Code : HPT

Prescription Use : Yes

Device Count : 1

- Catalog Number :

Device Description : This system adopts the most advanced Optical-electro-mechanical Integration tech This system adopts the most advanced Optical-electro-mechanical Integration technology. It integrates digital Fundus-Fluorescein-Angiography camera and digital-fundus-images acquisition and processing system, which can continuously display real-time, high quality color fundus images as well as black-white Fundus-Fluorescein-Angiography video images. The fundus images acquisition and processing system can process (full digital), record (real-time and completely) and save the color fundus images as well as retinal-fluorescein-angiography dynamic & static images into the computer. You can modify pictures, check reports, edit Graph-texts and manage all the dates at any time you want; you can measure and calculate the size of the case focus; you can zoom, move, stick, and put together the pictures; you can adjust the color on the picture, you can also record all the data on the CD, which can assistant scientific research and teaching. This system has combine function of many fundus image acquisition instruments, which can support medical treatments.

Device Class : 2

Duns Number: 543066376

Premarket Exempt : Yes

Product Code : HKI

Prescription Use : Yes

Device Count : 1

- Catalog Number :

Device Description : This system adopts the most advanced Optical-electro-mechanical Integration tech This system adopts the most advanced Optical-electro-mechanical Integration technology. It integrates digital Fundus-Fluorescein-Angiography camera and digital-fundus-images acquisition and processing system, which can continuously display real-time, high quality color fundus images as well as black-white Fundus-Fluorescein-Angiography video images. The fundus images acquisition and processing system can process (full digital), record (real-time and completely) and save the color fundus images as well as retinal-fluorescein-angiography dynamic & static images into the computer. You can modify pictures, check reports, edit Graph-texts and manage all the dates at any time you want; you can measure and calculate the size of the case focus; you can zoom, move, stick, and put together the pictures; you can adjust the color on the picture, you can also record all the data on the CD, which can assistant scientific research and teaching. This system has combine function of many fundus image acquisition instruments, which can support medical treatments.

Device Class : 2

Duns Number: 543066376

Premarket Exempt : Yes

Product Code : HKI

Prescription Use : Yes

Device Count : 1

- Catalog Number :

Device Description : The projection perimeter is used to check the sensitivity of the human eye to li The projection perimeter is used to check the sensitivity of the human eye to light(visual acuity). Ambient light by refraction system to the retina, the retinal photochemical reactions by bioelectrical, transmitted through the visual pathway visual cortex, the brain through a comprehensive analysis of the formation of vision. Any part of the distribution from the retina to the visual cortex nerve fibers, direction, known as the road lesions occur, it will be reflected in the vision, visual field changes according to the results of other tests and clinical, can analyze the site of the lesion, nature and prognosis

Device Class : 1

Duns Number: 543066376

Premarket Exempt : Yes

Product Code : HPT

Prescription Use : Yes

Device Count : 1