SenTec AG

Address:RINGSTRASSE 39,THERWIL Basel-Landschaft,CH

Want to know more about this Organization? Request more information now!


Filters
Device Class
Product Code
Premarket Exempt
Clear

Device Description : Stand alone monitor with colour display for continuous non-invasive vital parame Stand alone monitor with colour display for continuous non-invasive vital parameter monitoring, with integrated docking station for sensor storage and calibration.

Device Class : 2

Duns Number: 480797856

Premarket Exempt : No

Product Code : DPZ, DQA, KLK, LKD, LPP

Prescription Use : Yes

Device Count : 1

Device Description : Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The ad Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The adapter cable is available in different lengths (XXX=150 cm, 250 cm, 750 cm).

Device Class : 2

Duns Number: 480797856

Premarket Exempt : No

Product Code : DPZ, DQA, KLK, LKD, LPP

Prescription Use : Yes

Device Count : 1

- Catalog Number :

Device Description : The Ear Clip is required to attach SenTec TC Sensors to the patient’s earlobe. S The Ear Clip is required to attach SenTec TC Sensors to the patient’s earlobe. Suitable for patients with earlobes of sufficient size and mature, intact skin.

Device Class :

Duns Number: 480797856

Premarket Exempt : No

Product Code : DPZ, DQA, KLK, LKD, LPP

Prescription Use : Yes

Device Count : 1

Device Description : The Service Gas is required for the calibration of the PCO2-part of SenTec TC Se The Service Gas is required for the calibration of the PCO2-part of SenTec TC Sensors. Depending on usage of the SDMS one Service Gas cylinder lasts for approx. 3 to 4 weeks.

Device Class :

Duns Number: 480797856

Premarket Exempt : No

Product Code : DPZ, DQA, KLK, LKD, LPP

Prescription Use : Yes

Device Count : 1

Device Description : The Contact Gel is required for proper CO2 gas conduction from the patient’s ski The Contact Gel is required for proper CO2 gas conduction from the patient’s skin to the SenTec TC Sensors. Every time a SenTec TC Sensors is to be attached to the measurement site, one drop of Contact Gel must be applied to the center of the Sensor membrane.

Device Class : 2

Duns Number: 480797856

Premarket Exempt : No

Product Code : DPZ, DQA, KLK, LKD, LPP

Prescription Use : Yes

Device Count : 1

Device Description : The membrane and the electrolyte of SenTec TC Sensors must be changed periodical The membrane and the electrolyte of SenTec TC Sensors must be changed periodically. For this purpose the old sensor membrane must be removed, the sensor surface must be cleaned, new electrolyte must be applied and a new sensor membrane must be put on. The patented Membrane Changer (MC-R) is a tool that allows the user to carry out the whole membrane change process by 4 simple press-and-turn steps. To enable an economic and cost saving membrane change, the Membrane Changer after use can be reloaded with a new Membrane Changer Insert (MC-I).

Device Class :

Duns Number: 480797856

Premarket Exempt : No

Product Code : DPZ, DQA, KLK, LKD, LPP

Prescription Use : Yes

Device Count : 1

Device Description : Standard Starter Set contains:Ear Clips (EC-MI)Multi-Site Attachment Rings for m Standard Starter Set contains:Ear Clips (EC-MI)Multi-Site Attachment Rings for mature/intact skin (MAR-MI)Multi-Site Attachment Rings for sensitive/fragile skin (MAR-SF)Membrane Changer tool (reloadable) (MC-R)Contact Gel (GEL-04)Service Gas (GAS-0812)

Device Class : 2

Duns Number: 480797856

Premarket Exempt : No

Product Code : LPP, KLK, DQA, DPZ, LKD

Prescription Use : Yes

Device Count : 1

Device Description : Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The ad Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The adapter cable is available in different lengths (XXX=150 cm, 250 cm, 750 cm).

Device Class : 2

Duns Number: 480797856

Premarket Exempt : No

Product Code : DPZ, DQA, KLK, LKD, LPP

Prescription Use : Yes

Device Count : 1

Device Description : Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The ad Adapter cable to connect SenTec TC Sensors to the SenTec Digital Monitor. The adapter cable is available in different lengths (XXX=150 cm, 250 cm, 750 cm).

Device Class : 2

Duns Number: 480797856

Premarket Exempt : No

Product Code : DPZ, DQA, KLK, LKD, LPP

Prescription Use : Yes

Device Count : 1

Device Description : MAR-MI is intended to attach SenTec TC Sensors to various measurement sites for MAR-MI is intended to attach SenTec TC Sensors to various measurement sites for patients with mature, intact skin.

Device Class :

Duns Number: 480797856

Premarket Exempt : No

Product Code : DPZ, DQA, KLK, LKD, LPP

Prescription Use : Yes

Device Count : 1